capaNCDT CSH/SE Capacitive

capaNCDT CSH/SE: sensors and measurement devices by Micro-Epsilon for capacitive.

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of capaNCDT CSH/SE
Measuring window 0–2.4 mm
Resolution 0.000075–0.024 µm
Measuring range 0.5–1.2 mm
Linearity 0.25–1.2 µm
Recommended target diameter 5–17 mm
Active area size (as specified) 2.9–8.1 mm
Weight 0.03–0.038 kg
Number of measurement channels 1–4
Accuracy 0.25–1.2 µm
ADC sampling rate 1000–5000 samples/s

Models in the series

One column per model: what differs between the models of the series.

Models of capaNCDT CSH/SE compared by parameter
Parameter CSH-0,25/SE/CAm-1,4 CSH-0,5/SE/CAm-1,4 CSH-1,2/SE/CAm-1,4 CSH-1/SE/CAm-1,4 CSH-2/SE/CAm-1,4
Start of measuring range 0 mm 0 mm 0 mm 0 mm 0 mm
Operating temperature -269–200 °C -269–200 °C -269–200 °C -269–200 °C -269–200 °C
Recommended mounting position 3 mm 3 mm 3 mm 3 mm 3 mm
Outputs and interfaces 4-20mA Analog 0-10V Analog 0-10V Analog 0-10V Analog 0-10V
Measuring window 0–0.125 mm 0–1 mm 0–2.4 mm 0–1 mm 0–2 mm
Resolution 0.000075 µm 0.00015 µm 0.024 µm 0.0003 µm 0.0006 µm
Measuring range 0.5 mm 0.5 mm 1.2 mm 1 mm 1 mm
Interfaces Ethernet Ethernet Ethernet Ethernet Ethernet
Linearity 0.25 µm 0.35 µm 1.2 µm 0.6 µm 0.6 µm
Recommended target diameter 5 mm 7 mm 11 mm 11 mm 17 mm
Active area size (as specified) 2.9 mm 4.1 mm 6.3 mm 5.7 mm 8.1 mm
Sampling rate reference DT6120/IP: IP68 single-channel controller with 1 kHz analog bandwidth and up to 2 kSamples/s over RS485 DL6222: 20 kHz bandwidth; DT6222 digital rate 3.906 kSamples/s DL6228: 1 kHz bandwidth and 3.906 kSamples/s digital rate; optimized for CSE/HT sensors DL6510 with CPM6011: 8.5 kHz bandwidth in the official maximum-eight-channel DT6530 base system DT6110/IP: IP68 single-channel controller with 1 kHz bandwidth
Storage temperature -269–200 °C -269–200 °C -269–200 °C -269–200 °C -269–200 °C
Weight 0.03 kg 0.03 kg 0.033 kg 0.033 kg 0.038 kg
Protection class (DIN EN 60529) IP40 IP40 IP40 IP40 IP40
Linearity reference Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (2-channel base) + DL6510 + CP6001 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6230 + DL6230 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6230 + DL6220 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (8-channel base) + DL6510 + CPM6011 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6110/IP controller contribution.
Technical specification details 0-0.25 mm model-level measuring interval 0-0.5 mm model-level measuring interval 0-1.2 mm model-level measuring interval 0-1 mm model-level measuring interval 0-2 mm model-level measuring interval
Temperature stability (µm/K) -0.04 -0.05 -0.05 -0.06 -0.04
Number of measurement channels 1 1 4 4 2
Contact Non-contact Non-contact Non-contact Non-contact Non-contact
Accuracy 0.25 µm 0.35 µm 1.2 µm 0.6 µm 0.6 µm
ADC sampling rate 5000 samples/s 5000 samples/s 5000 samples/s 5000 samples/s 1000 samples/s
Status Active Active Active Active Active
Datasheet PDF — CSH-0,25/SE/CAm-1,4 (opens in a new tab) PDF — CSH-0,5/SE/CAm-1,4 (opens in a new tab) PDF — CSH-1,2/SE/CAm-1,4 (opens in a new tab) PDF — CSH-1/SE/CAm-1,4 (opens in a new tab) PDF — CSH-2/SE/CAm-1,4 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

These cylindrical titanium heads address very low temperatures, cleanrooms, UHV and strong magnetic fields. Select configuration limits from the exact specification.

No. It specifies an integral standard 1.4 m cable with a type B connector and still requires a suitable capaNCDT controller.

Linearity includes head and controller. Resolution references specified cable and bandwidth conditions, so assess the complete measurement chain.

No. Its table specifies IP40. Vacuum/material cleanliness does not substitute for dust and water ingress protection.

Use the recommended circumferential clamping position and account for heat transfer through surrounding material. Installation is part of the performance conditions.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words