Skip to content

capaNCDT DT61xx controllers Capacitive

capaNCDT DT61xx controllers: measurement controllers by Micro-Epsilon for capacitive.

Visit the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of capaNCDT DT61xx controllers
Operating temperature -20–60 °C
Storage temperature -20–75 °C
Linearity (% FSO) 0.05–0.1 %
Frequency response cutoff 1000–20000 Hz
Dynamic resolution (% FSO) 0.015–0.03 %
Static resolution (% FSO) 0.0007–0.0014 %

Models in the series

One column per model: what differs between the models of the series.

Models of capaNCDT DT61xx controllers compared by parameter
Parameter DT6110 DT6110/IP DT6112 DT6120 DT6120/IP
Protection class (DIN EN 60529) IP40 IP68 IP40 IP40 IP68
Operating temperature 10–60 °C -20–60 °C 10–60 °C 10–60 °C -20–60 °C
Storage temperature -10–75 °C -20–75 °C -10–75 °C -10–75 °C -20–75 °C
Number of measurement channels 1 1 1 1 1
Linearity (% FSO) 0.05 % 0.1 % 0.1 % 0.05 % 0.1 %
Analog output 0–10 V standard; ±5 V or 10–0 V optional 0–10 V / ±5 V voltage OR 4–20 mA current variant; select exact configuration 0–10 V standard; ±5 V or 10–0 V optional 0–10 V standard; ±5 V or 10–0 V optional 0–10 V / ±5 V voltage OR 4–20 mA current variant; select exact configuration
Frequency response cutoff Maximum rate with a compatible controller 1 kHz (−3 dB) 1 kHz (−3 dB) 20 kHz (−3 dB) 1 kHz (−3 dB) 1 kHz (−3 dB)
Dynamic resolution (% FSO) 0.015 % FSO (1 kHz) 0.02 % FSO (1 kHz) 0.03 % FSO (20 kHz) 0.015 % FSO (1 kHz) 0.02 % FSO (1 kHz)
Static resolution (% FSO) 0.0007 % FSO (2 Hz) 0.0009 % FSO (2 Hz) 0.0014 % FSO (2 Hz) 0.0007 % FSO (2 Hz) 0.0009 % FSO (2 Hz)
Channels 1 1 1 1 1
Interfaces Not specified Not specified Not specified RS-485 RS-485
Output update rate Not specified Not specified Not specified 2 kHz 2 kHz
Measuring rate Not specified Not specified Not specified 2 kHz (RS485 output) 2 kHz (RS485)
RS485 output resolution Not specified Not specified Not specified 24 bit 24 bit
Status Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

No. DT6110/DT6112 are analog paths, while DT6120 adds RS485. /IP variants and output configurations must also be selected by model.

No. It is the analog path’s −3 dB frequency response. Digital output rate is separately specified for supporting models such as DT6120.

No. Standard versions specify IP40; /IP versions specify IP68. Match the cable and connection to the variant.

No. The manufacturer defines channel linearity as the sum of controller and sensor linearity. Match bandwidth and measuring span as well.

The table specifies one measurement channel. Multiple heads require separate controllers or a suitable multichannel system; auxiliary connections are not extra measurement channels.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words