Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for DT6222
Linearity (% FSO) 0.1 %
Interfaces Ethernet
Output update rate 3.906 kHz
Number of measurement channels 4
Storage temperature -10–75 °C
Operating temperature 10–60 °C
Protection class (DIN EN 60529) IP40
Frequency response cutoff Maximum rate with a compatible controller 20 kHz (−3 dB)
Channels Up to 4 inputs; one module per sensor head
Analog output 0–10 V / 4–20 mA; select output path
Static resolution (% FSO) 0.0005 % FSO (RMS; 2 Hz; end-of-range reference)
Dynamic resolution (% FSO) 0.05 % FSO (RMS; 20 kHz)

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

Dimension (drawing reference) 75 mm
Dimension (drawing reference) 100 mm
Dimension (drawing reference) 125 mm
Dimension (drawing reference) 150 mm
Dimension (drawing reference) 90 mm
Request a quote for this product

Compatible system components

Accessories

  • DL6222
    Measuring rate
    Not specified
    Communication
    Not specified
    Inputs
    1
    Signal type
    Not specified
    Exact selected configuration, calibration range, mode and active requirements only.

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

Use the DT6222 basic module and DL6222 demodulators for up to 4 measuring channels. Supported channel count does not mean that all modules are included. Each channel also needs a suitable sensor head and cable.

No. The 20 kHz value is the bandwidth at −3 dB. The table lists a maximum digital measuring rate of 3.906 kHz. Using that bandwidth through an analogue output requires a suitable DAQ and an assessment of the complete measurement chain.

The manufacturer lists ±0.1% FSO linearity for the controller with DL6222. This is not the combined sensor-and-controller linearity; the manufacturer requires adding the sensor contribution on the same range basis.

The specification lists Ethernet and IP40 protection. Analogue 0–10 V and 4–20 mA outputs are listed separately. Select the acquisition path explicitly; an analogue connection does not make the output EtherCAT or PROFINET.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words