Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for DT6240
Interfaces PROFINET
Output update rate 3.906 kHz
Number of measurement channels 4
Storage temperature -10–75 °C
Operating temperature 10–60 °C
Protection class (DIN EN 60529) IP40
Frequency response cutoff Maximum rate with a compatible controller 5 kHz (−3 dB)
Channels Up to 4 inputs; one module per sensor head
Analog output 0–10 V / 4–20 mA; select output path

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

Dimension (drawing reference) 75 mm
Dimension (drawing reference) 100 mm
Dimension (drawing reference) 125 mm
Dimension (drawing reference) 150 mm
Dimension (drawing reference) 90 mm
Linearity (% FSO) 0.05 %
Linearity (% FSO) 0.025 %
Resolution (% FSO) 0.0004 %
Resolution (% FSO) 0.02 %
Resolution (% FSO) 0.0001 %
Resolution (% FSO) 0.005 %
Request a quote for this product

Compatible system components

Accessories

  • DL6220
    Measuring rate
    Not specified
    Communication
    Not specified
    Inputs
    1
    Signal type
    Not specified
    Exact selected configuration, calibration range, mode and active requirements only.
  • DL6230
    Measuring rate
    Not specified
    Communication
    Not specified
    Inputs
    1
    Signal type
    Not specified
    Exact selected configuration, calibration range, mode and active requirements only.

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

DT6240 supports up to 4 channels, but the installed demodulator modules determine the active channel count. Configure a basic module and a DL6220 or DL6230 module for each required channel, together with the appropriate sensor head and cable.

The controller table specifies linearity below ±0.05% FSO with DL6220 and below ±0.025% FSO with DL6230. These are controller-only ratings: total linearity is the sum of controller and sensor contributions. Resolution and synchronization characteristics also depend on the selected module.

The manufacturer distinguishes a 5 kHz analogue bandwidth from a maximum digital measuring rate of 3.906 kHz. Bandwidth is not a substitute for the measurement-value output rate. An analogue path also requires a separate assessment of the connected DAQ.

The listed digital interface for DT6240 is PROFINET, and the controller protection class is IP40. A sensor head’s ingress rating must not be assigned to the controller. System suitability also depends on the selected module, cables and connections.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words