capaNCDT DT6530 controllers Capacitive
capaNCDT DT6530 controllers: measurement controllers by Micro-Epsilon for capacitive.
Download the datasheet (opens in a new tab) Visit the Micro-Epsilon site (opens in a new tab)
Models in the series
One column per model: what differs between the models of the series.
| Parameter | DT6530 |
|---|---|
| Storage temperature | -10–75 °C |
| Protection class (DIN EN 60529) | IP20 |
| Operating temperature | 10–60 °C |
| Number of measurement channels | 2 |
| Interfaces | Ethernet, EtherCAT |
| Linearity (% FSO) | 0.025 % |
| Resolution (% FSO) | 0.00003 % |
| Output update rate | 7.8 kHz |
| Analog output | 0–10 V and (0)4–20 mA; select output path |
| Available base-channel capacities | 2-channel or 8-channel base; configuration-dependent |
| Frequency response cutoff Maximum rate with a compatible controller | 8.5 kHz (−3 dB) |
| Status | Active |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
No. The modular system combines a basic controller, one demodulator per sensor and the appropriate connections in a rack. The manufacturer specifies up to eight sensors.
DL6530 accepts the sensor connection directly. The DL6510 path uses a compatible external preamplifier. Select demodulator, preamplifier and that path’s performance as a system.
No. The table separates −3 dB bandwidth from measurement rate. It lists four channels at 7.8 kHz or eight at 3.9 kHz; also check protocol and operating mode.
No. The table distinguishes demodulator/preamplifier paths and static/dynamic bandwidth conditions. Use the performance of the selected chain.
The table specifies IP20 for the controller. This does not change the protection ratings of connected sensor heads or cables.
Get a quote or advice