Every engineering figure, laid out to scan quickly
| Linearity (% FSO) | Typical linearity < ±0.02% FSO; depends on sensor |
|---|---|
| Measuring rate | 8 kHz |
| Layers in multi-peak measurement | 1 layer |
| Power consumption | 9 W |
| Number of measurement channels | 2 |
| Storage temperature | -20–70 °C |
| Operating temperature | 5–50 °C |
| Protection class (DIN EN 60529) | IP40 |
| Weight | 0.67 kg |
| Controller operation and indicators | Web interface; multifunction button for interface selection, adjustable functions and factory reset after 10 s; 4 LEDs for intensity, range, link/data; /IE version LEDs show RUN and ERR instead of link/data. |
| Permissible ambient light | 30,000 lx |
| Adjustable measuring rate range | 100–8000 Hz |
| Controller light source | Internal white LED |
| Characteristic curves per channel | up to 10 characteristic curves for different sensors per channel, selected via menu table |
| Controller synchronisation | yes |
| Controller electrical connection | 3-pin supply terminal block; 5-pin Out/Trig terminal; 6-pin I/O terminal block (max. cable 30 m); 17-pin M12 for RS422/analog/encoder; RJ45 Ethernet (max. cable 100 m) |
| Controller housing material | Aluminum |
| Controller mounting | free-standing, DIN rail mounting |
| Controller indicators | Web interface; multifunction button; indicator LEDs (source table differs by family) |
| Analog output resolution | 16 bit — analog output, teachable span |
| RS422 output resolution | 18 bit — RS422 output |
| Ethernet output resolution | 1 nm — Ethernet output |
| Channels | 2 |
| Analog output | Voltage 0–5 V or 0–10 V; current 4–20 mA; two freely selectable outputs |
| Signal type | Analog voltage, Analog current, RS422, Digital (EtherCAT/Ethernet) |
Values by configuration
These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.
| Interfaces | RS422 |
|---|---|
| Interfaces | Ethernet |
The industries we serve