Skip to content

eddyNCDT 3001 Inductive (eddy current)

eddyNCDT 3001: sensors and measurement devices by Micro-Epsilon for inductive (eddy current).

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of eddyNCDT 3001
Protection class (DIN EN 60529) IP67
Storage temperature -20–80 °C
Upper cutoff frequency 5 kHz
Measuring range 4 mm
Number of measurement channels 1
Accuracy 28 µm
Linearity 28 µm
Resolution 4 µm
Minimum target diameter 48 mm
ADC sampling rate 75000 samples/s
Interfaces Ethernet
Supply voltage 12–32 V
End of measuring range 4.4 mm
Operating temperature 0–70 °C
Working distance 0.4–4.4 mm
Start of measuring range 0.4 mm

Models in the series

One column per model: what differs between the models of the series.

Models of eddyNCDT 3001 compared by parameter
Parameter DT3001-U2-A-SA DT3001-U2-M-SA DT3001-U4-A-SA DT3001-U4-M-SA DT3001-U6-A-SA DT3001-U6-M-SA DT3001-U8-A-SA DT3001-U8-M-SA
Protection class (DIN EN 60529) IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67
Storage temperature -20–80 °C -20–80 °C -20–80 °C -20–80 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C
Upper cutoff frequency 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz
Measuring range 2 mm 2 mm 4 mm 4 mm 6 mm 6 mm 8 mm 8 mm
Number of measurement channels 1 1 1 1 1 1 1 1
Accuracy 28 µm 28 µm 28 µm 28 µm 15 µm 15 µm 20 µm 20 µm
Linearity 28 µm 28 µm 28 µm 28 µm 15 µm 15 µm 20 µm 20 µm
Resolution 4 µm 4 µm 4 µm 4 µm 3 µm 3 µm 4 µm 4 µm
Minimum target diameter 48 mm 48 mm 48 mm 48 mm 72 mm 72 mm 72 mm 72 mm
ADC sampling rate 75000 samples/s 75000 samples/s 75000 samples/s 75000 samples/s 75000 samples/s 75000 samples/s 75000 samples/s 75000 samples/s
Interfaces Ethernet Ethernet EtherCAT Ethernet Ethernet EtherCAT EtherCAT EtherCAT
Supply voltage 12–32 V 12–32 V 12–32 V 12–32 V 12–32 V 12–32 V 12–32 V 12–32 V
End of measuring range 2.4 mm 2.4 mm 4.4 mm 4.4 mm 6.6 mm 6.6 mm 8.8 mm 8.8 mm
Operating temperature 0–70 °C 0–70 °C 0–70 °C 0–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C
Working distance 0.4–2.4 mm 0.4–2.4 mm 0.4–4.4 mm 0.4–4.4 mm 0.6–6.6 mm 0.6–6.6 mm 0.8–8.8 mm 0.8–8.8 mm
Start of measuring range 0.4 mm 0.4 mm 0.4 mm 0.4 mm 0.6 mm 0.6 mm 0.8 mm 0.8 mm
Calibration target material "Aluminum" "Steel" "Aluminum" "Steel" "Aluminum" "Steel" "Aluminum" "Steel"
Outputs and interfaces Analog 0-10V Analog 0-10V Digital I/O Analog 0-10V Digital I/O Digital I/O RS422 / RS485 Analog 0-10V
Technical specification details 0-2 mm model-level measuring interval 0-2 mm model-level measuring interval 0-4 mm model-level measuring interval 0-4 mm model-level measuring interval 0-6 mm model-level measuring interval 0-6 mm model-level measuring interval 0-8 mm model-level measuring interval 0-8 mm model-level measuring interval
Sampling rate reference Integrated DT3001 electronics: 75 kSamples/s, 5 kHz bandwidth Integrated DT3001 electronics: 75 kSamples/s, 5 kHz bandwidth Integrated DT3001 electronics: 75 kSamples/s, 5 kHz bandwidth Integrated DT3001 electronics: 75 kSamples/s, 5 kHz bandwidth Integrated DT3001 electronics: 75 kSamples/s, 5 kHz bandwidth Integrated DT3001 electronics: 75 kSamples/s, 5 kHz bandwidth Integrated DT3001 electronics: 75 kSamples/s, 5 kHz bandwidth Integrated DT3001 electronics: 75 kSamples/s, 5 kHz bandwidth
Sensor shielding "unshielded" "unshielded" "unshielded" "unshielded" "unshielded" "unshielded" "unshielded" "unshielded"
Status Active Active Active Active Active Active Active Active
Datasheet PDF — DT3001-U2-A-SA (opens in a new tab) PDF — DT3001-U2-M-SA (opens in a new tab) PDF — DT3001-U4-A-SA (opens in a new tab) PDF — DT3001-U4-M-SA (opens in a new tab) PDF — DT3001-U6-A-SA (opens in a new tab) PDF — DT3001-U6-M-SA (opens in a new tab) PDF — DT3001-U8-A-SA (opens in a new tab) PDF — DT3001-U8-M-SA (opens in a new tab)

Compatible accessories

Cables

  • PCx/5-M12 configurable component family Only for source configuration configuration-ef59e98edd09a24dcc4859f2: DT3001-U4-M-Cx; selected configuration must be matched before display.; 5 m standard; longer and drag-chain variants are optional. Not a sensor-controller extension.

Power supplies

  • PS2020 (2420062) Only for source configuration configuration-ef59e98edd09a24dcc4859f2: DT3001-U4-M-Cx; selected configuration must be matched before display.; Calculate continuous and startup current for the complete chain. Being listed does not guarantee enough current for every configuration; never substitute for a mains-powered controller supply.

Complementary products

  • IF1032/ETH Only for source configuration configuration-ef59e98edd09a24dcc4859f2: DT3001-U4-M-Cx; selected configuration must be matched before display.; Conditional option for analog-output sensors: confirm that the selected voltage/current range and wiring match the IF1032 analog input; Ethernet is provided by the module, not native to the sensor.

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The measuring controller is integrated into the sensor housing. Power and an analog-output connection are still required; connector versions need the matching cable.

No. The catalogue distinguishes a 75 kHz analog-output update rate from a 5 kHz frequency response at −3 dB.

No. U8 has a 0.8 mm start offset, giving a 0.8–8.8 mm measurement interval and an 8 mm net span.

They identify target-material calibrations: A for aluminum and M for steel. Changing material requires a suitable calibration, not one universal metal characteristic.

No. Minimum target diameter is 48 mm for U2/U4 and 72 mm for U6/U8. Check material and distance as well.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words