DT3005-U1-M-C1
From the eddyNCDT 3005 series
eddyNCDT 3005: sensors and measurement devices by Micro-Epsilon for inductive (eddy current).
- Number of measurement channels
- 1
Technical specification
Every engineering figure, laid out to scan quickly
| Measuring range | 1 mm |
|---|---|
| Start of measuring range | 0.1 mm |
| End of measuring range | 1.1 mm |
| Working distance | 0.1–1.1 mm |
| Linearity | 2.5 µm |
| Repeatability | 0.5 µm |
| Resolution | 0.5 µm |
| Minimum target diameter | 24 mm |
| Calibration target material | "Steel" |
| Supply voltage | 12–32 V |
| Number of measurement channels | 1 |
| Storage temperature | -20–80 °C |
| Operating temperature | -20–125 °C |
| Protection class (DIN EN 60529) | IP67 |
| Weight | 0.07 kg |
| Cable length | 1 m |
| Upper cutoff frequency | 5 kHz |
| Sensor shielding | "unshielded" |
| Technical specification details | 0-1 mm model-level measuring interval |
| Sensor temperature stability (µm/K) | 0.25 |
| Sampling rate reference | Integrated DT3005 electronics: 75 kSamples/s, 5 kHz bandwidth |
Values by configuration
These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.
| Interfaces | EtherCAT |
|---|---|
| Interfaces | Ethernet |
| Outputs and interfaces | Analog 0-10V |
| Outputs and interfaces | Digital I/O |
| Outputs and interfaces | 4-20mA |
| Outputs and interfaces | RS422 / RS485 |