Skip to content

eddyNCDT 3070 Inductive (eddy current)

eddyNCDT 3070: sensors and measurement devices by Micro-Epsilon for inductive (eddy current).

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Compatible accessories

Cables

  • PCx/8-M12 configurable component family Only for source configuration configuration-20a7469c5052a3aadb63cf48: ES-S04-C-CAx; selected configuration must be matched before display.; A 10 m drag-chain variant is listed separately; do not assume all standard lengths are drag-chain qualified.
  • PC5/8-M12/105 Only for source configuration configuration-20a7469c5052a3aadb63cf48: ES-S04-C-CAx; selected configuration must be matched before display.
  • SCD2/4/RJ45 Only for source configuration configuration-20a7469c5052a3aadb63cf48: ES-S04-C-CAx; selected configuration must be matched before display.
  • ECA-x/OE/mB0/D3,6 Only for source configuration configuration-20a7469c5052a3aadb63cf48: ES-S04-C-CAx; selected configuration must be matched before display.; OE version is soldered; mA0 version mates with the matching A0 sensor lead. Confirm total length, sensor connector and assembled-chain calibration. No universal length set is asserted.
  • ECA-x/mA0/mB0/D3,6 Only for source configuration configuration-20a7469c5052a3aadb63cf48: ES-S04-C-CAx; selected configuration must be matched before display.; OE version is soldered; mA0 version mates with the matching A0 sensor lead. Confirm total length, sensor connector and assembled-chain calibration. No universal length set is asserted.
  • 0323118 Only for source configuration configuration-20a7469c5052a3aadb63cf48: ES-S04-C-CAx; selected configuration must be matched before display.; Match the sensor-side connector and cable diameter; equal connector appearance does not establish capacitive/eddy-current interchangeability.
  • 0323141 Only for source configuration configuration-20a7469c5052a3aadb63cf48: ES-S04-C-CAx; selected configuration must be matched before display.; Match the sensor-side connector and cable diameter; equal connector appearance does not establish capacitive/eddy-current interchangeability.
  • 0323727 Only for source configuration configuration-20a7469c5052a3aadb63cf48: ES-S04-C-CAx; selected configuration must be matched before display.; Match the sensor-side connector and cable diameter; equal connector appearance does not establish capacitive/eddy-current interchangeability.
  • 0323174 Only for source configuration configuration-20a7469c5052a3aadb63cf48: ES-S04-C-CAx; selected configuration must be matched before display.; Match the sensor-side connector and cable diameter; equal connector appearance does not establish capacitive/eddy-current interchangeability.
  • 0323173 Only for source configuration configuration-20a7469c5052a3aadb63cf48: ES-S04-C-CAx; selected configuration must be matched before display.; Match the sensor-side connector and cable diameter; equal connector appearance does not establish capacitive/eddy-current interchangeability.
  • 0323121 Only for source configuration configuration-20a7469c5052a3aadb63cf48: ES-S04-C-CAx; selected configuration must be matched before display.; Match the sensor-side connector and cable diameter; equal connector appearance does not establish capacitive/eddy-current interchangeability.

Power supplies

  • PS2020 (2420062) Only for source configuration configuration-20a7469c5052a3aadb63cf48: ES-S04-C-CAx; selected configuration must be matched before display.; Calculate continuous and startup current for the complete chain. Being listed does not guarantee enough current for every configuration; never substitute for a mains-powered controller supply.

Complementary products

  • IF1032/ETH Only for source configuration configuration-20a7469c5052a3aadb63cf48: ES-S04-C-CAx; selected configuration must be matched before display.; Conditional option for analog-output sensors: confirm that the selected voltage/current range and wiring match the IF1032 analog input; Ethernet is provided by the module, not native to the sensor.

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It supports very short ranges and miniature heads. Select head range, target material, geometry and environment together with a DT307x controller.

It is the digital update rate. Frequency response is up to 20 kHz and analog update is 200 kHz; do not merge these specifications.

DT3070 linearity is <±0.2% FSO after three-point linearization; DT3071 is <±0.1% FSO after five points, with additional capabilities.

No. ES-S04 is specified as IP50, while the tabulated EU05/ES08 are IP64 under the connection conditions. Controller IP does not rate the head.

The manufacturer requires special LC calibration for these heads with DT307x. A matching connector does not replace calibration.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words