eddyNCDT SGS4701 Inductive (eddy current)

eddyNCDT SGS4701: sensors and measurement devices by Micro-Epsilon for inductive (eddy current).

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of eddyNCDT SGS4701
Output update rate 64 kHz
Operating temperature 10–70 °C
Minimum target size (as specified) 3.5–6 mm
Working distance 0.05–0.6 mm
Minimum target diameter 3.5–6 mm
Measuring range 0.25–0.5 mm
Start of measuring range 0.05–0.1 mm
End of measuring range 0.3–0.6 mm

Models in the series

One column per model: what differs between the models of the series.

Models of eddyNCDT SGS4701 compared by parameter
Parameter SGS4701 (250 µm option) SGS4701 (500 µm)
Output update rate Not specified Not specified
Operating temperature 0–90 °C 0–90 °C
Sampling rate reference SGS4701 analog displacement output: 64 kSamples/s with 2 kHz frequency response SGS4701 analog displacement output: 64 kSamples/s with 2 kHz frequency response
Resolution 0.5 µm 0.5 µm
Upper cutoff frequency 2 kHz 2 kHz
Number of measurement channels 1 1
Linearity 2 µm 2 µm
Weight 0.085 kg 0.085 kg
Minimum target size (as specified) 3.5 mm 6 mm
Power consumption 0.6 W 0.6 W
Protection class (DIN EN 60529) IP67 IP67
Outputs and interfaces Analog 0-10V Analog 0-10V
Technical specification details 0-0.25 mm model-level measuring interval 0-0.5 mm model-level measuring interval
Working distance 0.05–0.3 mm 0.1–0.6 mm
Minimum target diameter 3.5 mm 6 mm
Measuring range 0.25 mm 0.5 mm
Cable length 1 m 1 m
Supply voltage 12–32 V 12–32 V
Start of measuring range 0.05 mm 0.1 mm
Sensor temperature stability (% FSO/K) 0.015 0.015
End of measuring range 0.3 mm 0.6 mm
Sensor cable may be shortened false false
Contact Non-contact Non-contact
Accuracy 2 µm 2 µm
ADC sampling rate 64000 samples/s 64000 samples/s
Status Active Active
Datasheet PDF — SGS4701 (250 µm option) (opens in a new tab) PDF — SGS4701 (500 µm) (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It measures machine-tool spindle growth caused by thermal and centrifugal effects, using a suitable ring as target, with an additional temperature output.

The net span is 500 µm with a 100 µm start offset, giving a 100–600 µm interval from the head.

Do not transfer it automatically. The 250 µm OEM option is a separate configuration and needs performance evidence explicitly covering it.

No. The manufacturer prohibits shortening it. Head, cable and controller form a calibrated system; choose the cable configuration beforehand.

No. Analog update is 64 kHz, while frequency response is 2 kHz. Use frequency response for dynamic-measurement planning.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words