Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of IFS2403
Minimum target thickness 0.06–1.5 mm
Measuring range 0.4–10 mm
Resolution 0.03–0.46 µm
Accuracy 0.3–8 µm
Light spot diameter 0.009–0.056 mm
Start of measuring range 2.5–14.7 mm
Maximum measuring angle 6–20 deg
Number of measurement channels 1–2
Linearity 0.12–4 µm
ADC sampling rate 8000–30000 samples/s

Models in the series

One column per model: what differs between the models of the series.

Models of IFS2403 compared by parameter
Parameter IFS2403-0.4 IFS2403-1.5 IFS2403-10 IFS2403-4 IFS2403/90-1.5 IFS2403/90-10 IFS2403/90-4
Technical specification details 0.4 mm net measuring range 1.5 mm net measuring range 10 mm net measuring range 4 mm net measuring range 1.5 mm net measuring range 10 mm net measuring range 4 mm net measuring range
Linearity reference https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity.
Protection class (DIN EN 60529) IP40 IP64 IP40 IP40 IP40 IP64 IP64
Target material reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass)
Sampling rate reference IFC2465: 30,000 measurements/s IFC2421MP: 10,000 measurements/s IFC2465: 30,000 measurements/s IFC2416: 25,000 measurements/s IFC2422: 10,000 measurements/s per synchronous channel IFC2417: 25,000 measurements/s per synchronous channel IFC2417: 25,000 measurements/s per synchronous channel
Outputs and interfaces 4-20mA Analog 0-10V Analog 0-10V Digital I/O Analog 0-10V RS422 / RS485 Digital I/O
Operating temperature 5–70 °C 5–70 °C 5–70 °C 5–70 °C 5–70 °C 5–70 °C 5–70 °C
Minimum target thickness 0.06 mm 0.23 mm 1.5 mm 0.6 mm 0.23 mm 1.5 mm 0.6 mm
Measuring range 0.4 mm 1.5 mm 10 mm 4 mm 1.5 mm 10 mm 4 mm
Resolution 0.047 µm 0.03 µm 0.125 µm 0.05 µm 0.186 µm 0.125 µm 0.46 µm
Accuracy 0.3 µm 1.2 µm 8 µm 3 µm 1.2 µm 8 µm 3 µm
Numerical aperture (NA) 0.5 0.3 0.15 0.15 0.3 0.15 0.15
Light spot diameter 0.009 mm 0.015 mm 0.056 mm 0.028 mm 0.015 mm 0.056 mm 0.028 mm
Start of measuring range 2.5 mm 8 mm 11 mm 14.7 mm 4.9 mm 8.6 mm 12 mm
Mounting Radial clamping (mounting adapter see accessories) Radial clamping (mounting adapter see accessories) Radial clamping (mounting adapter see accessories) Radial clamping (mounting adapter see accessories) Radial clamping (mounting adapter see accessories) Radial clamping (mounting adapter see accessories) Radial clamping (mounting adapter see accessories)
Weight 0.2 kg 0.2 kg 0.2 kg 0.2 kg 0.2 kg 0.2 kg 0.2 kg
Interfaces EtherCAT Ethernet EtherCAT Ethernet Ethernet EtherCAT EtherCAT
Maximum measuring angle 20 deg 16 deg 6 deg 6 deg 16 deg 6 deg 6 deg
Number of measurement channels 1 2 1 2 1 2 2
Linearity 0.12 µm 0.45 µm 4 µm 1.6 µm 0.45 µm 4 µm 1.6 µm
Storage temperature -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C
Contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact
ADC sampling rate 10000 samples/s 25000 samples/s 30000 samples/s 8000 samples/s 25000 samples/s 8000 samples/s 8000 samples/s
Status Active Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

They are 8 mm diameter hybrid confocal heads with axial or radial beam paths. The table lists 0.4, 1.5, 4 and 10 mm model-dependent ranges.

No. The maximum angle is a usable-signal limit on reflective surfaces. The footnote states that accuracy decreases towards that limit.

The value is range-specific and refers to glass with refractive index n=1.5 at mid-range. It must not be generalized to every material or position.

The head includes a 2 m fiber and E2000/APC connector. Controller connection and any extension must follow the manufacturer conditions, including bending radius.

It refers to the front of the head, not the entire controller and connection assembly. The head operating temperature is +5 to +70°C.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words