Skip to content

IFS2405

IFS2405: sensors and measurement devices by Micro-Epsilon for distance & displacement sensors.

Visit the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of IFS2405
Maximum measuring angle 5–34 deg
Light spot diameter 0.006–0.06 mm
Weight 0.125–1.2 kg
Resolution 0.004–0.747 µm
Number of measurement channels 1–2
Linearity 0.09–5.6 µm
Measuring range 0.3–30 mm
Start of measuring range 6–220 mm
Minimum target thickness 0.015–2.2 mm
ADC sampling rate 8000–30000 samples/s
Accuracy 0.09–9 µm

Models in the series

One column per model: what differs between the models of the series.

Models of IFS2405 compared by parameter
Parameter IFS2405-0.3 IFS2405-1 IFS2405-10 IFS2405-28 IFS2405-28/VAC(001) IFS2405-3 IFS2405-30 IFS2405-6 IFS2405/90-6
Numerical aperture (NA) 0.6 0.55 0.3 0.1 0.1 0.45 0.2 0.22 0.22
Storage temperature -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C
Maximum measuring angle 34 deg 30 deg 17 deg 5 deg 5 deg 24 deg 9 deg 10 deg 10 deg
Light spot diameter 0.006 mm 0.008 mm 0.016 mm 0.06 mm 0.06 mm 0.009 mm 0.05 mm 0.031 mm 0.031 mm
Protection class (DIN EN 60529) IP40 IP64 IP40 IP64 IP40 IP40 IP64 IP64 IP64
Weight 0.14 kg 0.125 kg 0.5 kg 0.75 kg 1.2 kg 0.225 kg 0.73 kg 0.26 kg 0.315 kg
Resolution 0.018 µm 0.004 µm 0.018 µm 0.065 µm 0.747 µm 0.008 µm 0.53 µm 0.017 µm 0.19 µm
Interfaces EtherCAT PROFINET EtherCAT EtherCAT Not specified EtherCAT EtherCAT EtherCAT Ethernet
Sampling rate reference IFC2421: 10,000 measurements/s IFC2421MP: 10,000 measurements/s IFC2422MP: 10,000 measurements/s per synchronous channel IFC2411: 8,000 measurements/s Not specified IFC2417: 25,000 measurements/s per synchronous channel IFC2466: 30,000 measurements/s per synchronous channel IFC2417: 25,000 measurements/s per synchronous channel IFC2421: 10,000 measurements/s
Technical specification details 0.3 mm net measuring range 1 mm net measuring range 10 mm net measuring range 28 mm net measuring range Not specified 3 mm net measuring range 30 mm net measuring range 6 mm net measuring range 6 mm net measuring range
Number of measurement channels 1 2 1 2 Not specified 2 1 1 2
Linearity 0.09 µm 0.2 µm 1.5 µm 5.6 µm Not specified 0.6 µm 4.5 µm 1.2 µm 1.2 µm
Operating temperature 5–70 °C 5–70 °C 5–70 °C 5–70 °C 5–70 °C 5–70 °C 5–70 °C 5–70 °C 5–70 °C
Target material reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass) reflective, diffuse as well as transparent surfaces (e.g. glass)
Linearity reference https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. Not specified https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity.
Measuring range 0.3 mm 1 mm 10 mm 28 mm 28 mm 3 mm 30 mm 6 mm 6 mm
Mounting Radial clamping (mounting adapter see accessories) Radial clamping (mounting adapter see accessories) Radial clamping (mounting adapter see accessories) Radial clamping (mounting adapter see accessories) Radial clamping (mounting adapter see accessories) Radial clamping (mounting adapter see accessories) Radial clamping (mounting adapter see accessories) Radial clamping (mounting adapter see accessories) Radial clamping (mounting adapter see accessories)
Start of measuring range 6 mm 10 mm 50 mm 220 mm 220 mm 20 mm 100 mm 63 mm 41 mm
Minimum target thickness 0.015 mm 0.05 mm 0.5 mm 2.2 mm 2.2 mm 0.15 mm 1.5 mm 0.3 mm 0.3 mm
Outputs and interfaces RS422 / RS485 RS422 / RS485 RS422 / RS485 Analog 0-10V Not specified RS422 / RS485 Digital I/O Digital I/O Digital I/O
Contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact
ADC sampling rate 25000 samples/s 25000 samples/s 8000 samples/s 30000 samples/s Not specified 10000 samples/s 10000 samples/s 30000 samples/s 25000 samples/s
Accuracy 0.09 µm 0.3 µm 3 µm 8.4 µm Not specified 0.9 µm 9 µm 1.8 µm 1.2 µm
Working distance Not specified Not specified Not specified Not specified Not specified 5–30 mm Not specified Not specified Not specified
Status Active Active Active Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It is a universal confocal-head family for distance and one-sided transparent thickness, with short and long spans and radial-beam versions.

No. It depends on model and span, and accuracy decreases towards the angle limit. Select for the actual target slope.

The table includes IFS2405-28/VAC(001) with a specific housing, environment suitability and IP40. Vacuum suitability must not be assigned to every head in the family.

Not as specified. Static resolution uses 2048-value averaging at 1 kHz at mid-range. Dynamic resolution is specified separately as RMS noise.

Add a compatible fiber for its FC socket and a suitable confocalDT controller. Thickness selection also requires minimum thickness, refractive index and working range.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words