IFS2407 HT

IFS2407 HT: sensors and measurement devices by Micro-Epsilon for distance & displacement sensors.

Visit the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of IFS2407 HT
Operating temperature 5–200 °C
Accuracy 0.16–1.6 µm
Number of measurement channels 1–2
ADC sampling rate 8000–70000 samples/s
Resolution 0.01–0.18 µm
Weight 0.04–0.05 kg
Start of measuring range 2–14.5 mm
Light spot diameter 0.011–0.029 mm
Measuring range 0.8–4 mm
Minimum target thickness 0.04–0.2 mm

Models in the series

One column per model: what differs between the models of the series.

Models of IFS2407 HT compared by parameter
Parameter IFS2407-0.8HT IFS2407-0.8HT/VAC IFS2407-2HT IFS2407-2HT/VAC IFS2407-4HT IFS2407-4HT/VAC IFS2407/90-0.8HT IFS2407/90-2HT IFS2407/90-2HT/VAC IFS2407/90-4HT IFS2407/90-4HT/VAC
Outputs and interfaces Analog 0-10V Not specified Analog 0-10V Not specified RS422 / RS485 Not specified Digital I/O Analog 0-10V Not specified Analog 0-10V Not specified
Operating temperature 5–70 °C 5–200 °C 5–70 °C 5–70 °C 5–70 °C 5–200 °C 5–70 °C 5–70 °C 5–70 °C 5–70 °C 5–70 °C
Accuracy 0.16 µm 0.3 µm 0.4 µm 0.8 µm 0.8 µm 1.6 µm 0.16 µm 0.4 µm 0.8 µm 0.8 µm 1.6 µm
Interfaces EtherCAT EtherCAT EtherCAT Ethernet Ethernet Ethernet Ethernet EtherCAT Ethernet Ethernet EtherCAT
Linearity reference https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. Stored as the conservative published family/model accuracy for catalog filtering. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. Stored as the conservative published family/model accuracy for catalog filtering. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. Stored as the conservative published family/model accuracy for catalog filtering. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. Stored as the conservative published family/model accuracy for catalog filtering. https://www.micro-epsilon.com/fileadmin/download/products/cat--confocalDT--en-us.pdf published optical-probe linearity; axial resolution is not substituted for linearity. Stored as the conservative published family/model accuracy for catalog filtering.
Sampling rate reference IFC2412: 8,000 measurements/s per synchronous channel Maximum mapped family rate 70,000 Hz; verify the exact model and operating mode. IFC2422: 10,000 measurements/s per synchronous channel Maximum mapped family rate 70,000 Hz; verify the exact model and operating mode. IFC2422: 10,000 measurements/s per synchronous channel Maximum mapped family rate 70,000 Hz; verify the exact model and operating mode. IFC2422: 10,000 measurements/s per synchronous channel IFC2421MP: 10,000 measurements/s Maximum mapped family rate 70,000 Hz; verify the exact model and operating mode. IFC2411: 8,000 measurements/s Maximum mapped family rate 70,000 Hz; verify the exact model and operating mode.
Protection class (DIN EN 60529) IP64 IP40 IP40 IP40 IP40 IP64 IP64 IP40 IP40 IP64 IP40
Technical specification details 0.8 mm net measuring range 0-0.8 mm mapped range. Official vacuum-compatible sensor construction. 2 mm net measuring range 0-2 mm mapped range. Official vacuum-compatible sensor construction. 4 mm net measuring range 0-4 mm mapped range. Official vacuum-compatible sensor construction. 0.8 mm net measuring range 2 mm net measuring range 0-2 mm mapped range. Official vacuum-compatible sensor construction. 4 mm net measuring range 0-4 mm mapped range. Official vacuum-compatible sensor construction.
Number of measurement channels 1 Not specified 2 Not specified 1 Not specified 1 2 Not specified 1 Not specified
Contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact
ADC sampling rate 30000 samples/s 70000 samples/s 10000 samples/s 70000 samples/s 30000 samples/s 70000 samples/s 10000 samples/s 10000 samples/s 70000 samples/s 8000 samples/s 70000 samples/s
Resolution Not specified 0.045 µm Not specified 0.01 µm Not specified 0.18 µm Not specified Not specified 0.012 µm Not specified 0.02 µm
Numerical aperture (NA) Not specified 0.5 Not specified 0.28 Not specified 0.19 Not specified Not specified 0.28 Not specified 0.19
Weight Not specified 0.04 kg Not specified 0.04 kg Not specified 0.04 kg Not specified Not specified 0.05 kg Not specified 0.05 kg
Start of measuring range Not specified 5.85 mm Not specified 14.5 mm Not specified 14.5 mm Not specified Not specified 2 mm Not specified 2 mm
Mounting Not specified Clamping / screw connection via four mounting holes M2x0.4 Not specified Clamping / screw connection via four mounting holes M2x0.4 Not specified Clamping / screw connection via four mounting holes M2x0.4 Not specified Not specified Clamping / screw connection via four mounting holes M2x0.4 Not specified Clamping / screw connection via four mounting holes M2x0.4
Storage temperature Not specified -20–200 °C Not specified -20–200 °C Not specified -20–200 °C Not specified Not specified -20–200 °C Not specified -20–200 °C
Sampling rate limited by system readout Not specified True Not specified True Not specified True Not specified Not specified True Not specified True
Light spot diameter Not specified 0.011 mm Not specified 0.019 mm Not specified 0.029 mm Not specified Not specified 0.019 mm Not specified 0.029 mm
Measuring range Not specified 0.8 mm Not specified 2 mm Not specified 4 mm Not specified Not specified 2 mm Not specified 4 mm
Target material Not specified reflective, diffuse as well as transparent surfaces (e.g. glass) Not specified reflective, diffuse as well as transparent surfaces (e.g. glass) Not specified reflective, diffuse as well as transparent surfaces (e.g. glass) Not specified Not specified reflective, diffuse as well as transparent surfaces (e.g. glass) Not specified reflective, diffuse as well as transparent surfaces (e.g. glass)
Minimum target thickness Not specified 0.04 mm Not specified 0.1 mm Not specified 0.2 mm Not specified Not specified 0.1 mm Not specified 0.2 mm
Status Active Active Active Active Active Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It addresses temperatures up to 200°C and vacuum applications up to UHV. Fiber, feedthrough and mounting must also match the installation conditions.

Spans are 0.8, 2 and 4 mm. Start distance is separate and also differs between axial and /90 versions. Select both dimensions by model.

No. The table specifies IP40 alongside vacuum compatibility. Vacuum suitability does not imply a higher water-protection rating.

Yes. The manufacturer qualifies temperature stability by the clamping position. Follow the selected head’s mounting location and instructions.

No. It is a head with an FC socket for a detachable fiber. A complete system needs a compatible fiber and confocalDT controller plus installation accessories.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words