Skip to content

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of induSENSOR DTD
Measuring range 2–20 mm
Linearity 1–10 µm
Repeatability 0.15–1.5 µm
Accuracy 1–10 µm

Models in the series

One column per model: what differs between the models of the series.

Models of induSENSOR DTD compared by parameter
Parameter DTD-10G8 DTD-1G8 DTD-3G8 DTD-5G8
Outputs and interfaces 4-20mA RS422 / RS485 RS422 / RS485 4-20mA
Interfaces RS-485 PROFINET RS-485 Ethernet
Measuring range 20 mm 2 mm 6 mm 10 mm
Technical specification details 0-20 mm model-level measuring interval 0-2 mm model-level measuring interval 0-6 mm model-level measuring interval 0-10 mm model-level measuring interval
Sampling rate reference Integrated DTD cable controller controller Integrated DTD cable controller controller Integrated DTD cable controller controller Integrated DTD cable controller controller
Linearity 10 µm 1 µm 3 µm 5 µm
Linearity reference Official Micro-Epsilon induSENSOR DTD data: independent linearity for the exact DTD-xG8 model. Official Micro-Epsilon induSENSOR DTD data: independent linearity for the exact DTD-xG8 model. Official Micro-Epsilon induSENSOR DTD data: independent linearity for the exact DTD-xG8 model. Official Micro-Epsilon induSENSOR DTD data: independent linearity for the exact DTD-xG8 model.
Repeatability 1.5 µm 0.15 µm 0.45 µm 0.75 µm
Repeatability reference Official Micro-Epsilon induSENSOR DTD data: repeatability, 200 repetitions with each repetition averaged over 100 values. Official Micro-Epsilon induSENSOR DTD data: repeatability, 200 repetitions with each repetition averaged over 100 values. Official Micro-Epsilon induSENSOR DTD data: repeatability, 200 repetitions with each repetition averaged over 100 values. Official Micro-Epsilon induSENSOR DTD data: repeatability, 200 repetitions with each repetition averaged over 100 values.
Number of measurement channels 1 1 1 1
Contact Contact Contact Contact Contact
ADC sampling rate 300 samples/s 300 samples/s 300 samples/s 300 samples/s
Accuracy 10 µm 1 µm 3 µm 5 µm
Resolution (% FSO) Not specified 0.024 % Not specified Not specified
Published resolution (bits) Not specified 13 bit Not specified Not specified
Status Active Active Active Active
Datasheet PDF — DTD-10G8 (opens in a new tab) PDF — DTD-1G8 (opens in a new tab) PDF — DTD-3G8 (opens in a new tab) PDF — DTD-5G8 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The described system has a plain-bearing guided-plunger gauge and compact controller connected by a three-metre cable.

Optional interface modules support Ethernet, PROFINET and EtherCAT; include the appropriate module in the system configuration.

It is specified as adjustable −3 dB frequency response up to 300 Hz, not automatically as digital output rate.

Yes. The described gauge has a guided plunger and uses the LVDT principle. Match travel and installation to target contact.

No. The page lists them separately. Match repeatability requirements to repeatability and span-deviation requirements to model linearity.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words