Skip to content

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of mainSENSOR
Operating temperature -20–120 °C
Measuring range 12–55 mm
Upper cutoff frequency 1000–5000 Hz
Accuracy (% FSO) 3–9 %
Start of measuring range 1–5 mm
ADC sampling rate 1000–5000 samples/s
Linearity (% FSO) 5–9 %
Weight 0.0015–0.0045 kg
Current consumption 8.5–35 mA

Models in the series

One column per model: what differs between the models of the series.

Models of mainSENSOR compared by parameter
Parameter MDS-35-M12-CA-HT MDS-35-M12-SA-HT MDS-40-D18-SA MDS-40-LP-F MDS-40-LP-SUS MDS-40-MK-SA8-I MDS-40-MK-SR0-F MDS-40-MK-SR7-U10 MDS-40-MK-SR7-U45R MDS-45-M12-CA MDS-45-M12-SA MDS-45-M18-HP-SA MDS-45-M18-SA MDS-45-M18-SA(01) MDS-45-M30-SA
Outputs and interfaces Analog 0-10V Analog 0-10V Voltage 2 ±0.4 ... 9.6 ±0.4 V; current 4 ±0.8 ... 19.2 ±0.8 mA RS422 / RS485 Rectangular output; period duration 2.0 ... 3.3 ms RS422 / RS485 Digital I/O 4-20mA Digital I/O Digital I/O Analog 0-10V 4-20mA 4-20mA 4-20mA Voltage 2 ±0.2 ... 9.6 ±0.4 V; current 4 ±0.4 ... 19.2 ±0.8 mA
Technical specification details 0-35 mm model-level measuring interval 0-35 mm model-level measuring interval 0-40 mm model-level measuring interval 0-40 mm model-level measuring interval 0-40 mm model-level measuring interval 0-30 mm model-level measuring interval 0-30 mm model-level measuring interval 0-30 mm model-level measuring interval 0-30 mm model-level measuring interval 0-45 mm model-level measuring interval 0-45 mm model-level measuring interval 0-45 mm model-level measuring interval 0-45 mm model-level measuring interval 0-45 mm model-level measuring interval 0-45 mm model-level measuring interval
Operating temperature -20–120 °C -20–120 °C -20–80 °C -20–85 °C -20–85 °C -20–80 °C -20–80 °C -20–80 °C -20–80 °C -20–80 °C -20–80 °C -20–80 °C -20–80 °C -20–80 °C -20–80 °C
Sampling rate reference Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller Integrated electronics controller
Measuring range 12 mm 22 mm 30 mm 40 mm 40 mm 25 mm 50 mm 25 mm 30 mm 35 mm 52 mm 55 mm 33 mm 55 mm 33 mm
Interfaces Ethernet EtherCAT Ethernet Ethernet EtherCAT Ethernet EtherCAT Ethernet EtherCAT EtherCAT EtherCAT Ethernet EtherCAT Ethernet EtherCAT
Upper cutoff frequency 5 kHz 5 kHz 1 kHz Not specified Not specified 1 kHz Not specified 1 kHz 1 kHz 3 kHz 3 kHz 3 kHz 3 kHz 3 kHz 1 kHz
Accuracy (% FSO) 5 % 5 % 5 % 9 % 6 % 5 % 5 % 5 % 5 % 3 % 3 % 3 % 3 % 3 % 3 %
Protection class (DIN EN 60529) IP67 IP67 IP67 Not specified Not specified IP67 IP20 IP67 IP20 IP67 IP67 IP67 IP67 IP67 IP67
Magnet included (code) MB35HT MB35HT RL21 Not specified Not specified RL21 RL21 RL21 RL21 MB45 MB45 MB45 MB45 Not specified MB45
Start of measuring range 1 mm 1 mm 1.5 mm Not specified Not specified 1.5 mm 1.5 mm 1.5 mm 1.5 mm 5 mm 5 mm 2.25 mm 2.25 mm 2.25 mm 4 mm
Contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact
ADC sampling rate 5000 samples/s 5000 samples/s 1000 samples/s 1000 samples/s 1000 samples/s 1000 samples/s 1000 samples/s 1000 samples/s 1000 samples/s 5000 samples/s 5000 samples/s 3000 samples/s 3000 samples/s 3000 samples/s 1000 samples/s
Repeatability (% FSO) Not specified Not specified 0.05 % Not specified 0.05 % 0.05 % Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Linearity (% FSO) Not specified Not specified 5 % 9 % 6 % Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Resolution (% FSO) Not specified Not specified Not specified 0.05 % 0.05 % 0.05 % Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Weight Not specified Not specified Not specified 0.0015 kg 0.0045 kg Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Supply voltage Not specified Not specified Not specified 3.6–5.3 V 3.6–5.3 V Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Storage temperature Not specified Not specified Not specified -20–85 °C -20–85 °C Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Integration requirements Not specified Not specified Not specified EMC and ESD protection and voltage stabilization must be provided externally if required. EMC and ESD protection and voltage stabilization must be provided externally if required. Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Current consumption Not specified Not specified Not specified Not specified Not specified 35 mA 8.5 mA 13 mA 16 mA Not specified Not specified Not specified Not specified Not specified Not specified
Status Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — MDS-35-M12-CA-HT (opens in a new tab) PDF — MDS-35-M12-SA-HT (opens in a new tab) PDF — MDS-40-D18-SA (opens in a new tab) PDF — MDS-40-LP-F (opens in a new tab) PDF — MDS-40-LP-SUS (opens in a new tab) PDF — MDS-40-MK-SA8-I (opens in a new tab) PDF — MDS-40-MK-SR0-F (opens in a new tab) PDF — MDS-40-MK-SR7-U10 (opens in a new tab) PDF — MDS-40-MK-SR7-U45R (opens in a new tab) PDF — MDS-45-M12-CA (opens in a new tab) PDF — MDS-45-M12-SA (opens in a new tab) PDF — MDS-45-M18-HP-SA (opens in a new tab) PDF — MDS-45-M18-SA (opens in a new tab) PDF — MDS-45-M18-SA(01) (opens in a new tab) PDF — MDS-45-M30-SA (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The selected magnet determines the range; the manufacturer describes 20–55 mm options using different specified magnets.

No. Its continuous linear distance signal supports displacement measurement rather than only presence detection.

Yes. It measures distance to a suitable target magnet. Match magnet to range and geometry rather than assuming all magnets provide identical performance.

The manufacturer describes measurement through non-ferromagnetic materials such as aluminium. This does not establish suitability through ferromagnetic steel.

No. It measures the magnet without contact. Install magnet and sensor so distance and motion remain within the selected configuration.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words