Skip to content

optoNCDT 1220 Laser triangulation

optoNCDT 1220: sensors and measurement devices by Micro-Epsilon for laser triangulation.

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of optoNCDT 1220
Repeatability 1–50 µm
Selectable measuring rates 250–2000 Hz
Start of measuring range 20–100 mm
Working distance 20–600 mm
End of measuring range 30–600 mm
Linearity 10–1500 µm
Measuring range 10–500 mm
Light spot width Y 0.05–0.91 mm
Light spot width X 0.045–0.71 mm
Accuracy 10–1500 µm

Models in the series

One column per model: what differs between the models of the series.

Models of optoNCDT 1220 compared by parameter
Parameter ILD1220-10 ILD1220-10-IO-Link ILD1220-100 ILD1220-100-IO-Link ILD1220-200 ILD1220-200-IO-Link ILD1220-25 ILD1220-25-IO-Link ILD1220-50 ILD1220-50-IO-Link ILD1220-500 ILD1220-500-IO-Link
Repeatability 1 µm 1 µm 10 µm 10 µm 20 µm 20 µm 2.5 µm 2.5 µm 5 µm 5 µm 50 µm 50 µm
Selectable measuring rates 1 kHz Not specified 500 Hz Not specified 2 kHz Not specified 250 Hz Not specified 500 Hz Not specified 1 kHz Not specified
Interfaces RS422 IO-Link RS422 IO-Link RS422 IO-Link RS422 IO-Link RS422 IO-Link RS422 IO-Link
Outputs and interfaces RS422 / RS485 Not specified Analog 0-10V Not specified 4-20mA Not specified RS422 / RS485 Not specified 4-20mA Not specified RS422 / RS485 Not specified
Start of measuring range 20 mm 20 mm 50 mm 50 mm 60 mm 60 mm 25 mm 25 mm 35 mm 35 mm 100 mm 100 mm
Operating temperature 0–50 °C Not specified 0–50 °C Not specified 0–50 °C Not specified 0–50 °C Not specified 0–50 °C Not specified 0–50 °C Not specified
Working distance 20–30 mm Not specified 50–150 mm Not specified 60–260 mm Not specified 25–50 mm Not specified 35–85 mm Not specified 100–600 mm Not specified
End of measuring range 30 mm 30 mm 150 mm 150 mm 260 mm 260 mm 50 mm 50 mm 85 mm 85 mm 600 mm 600 mm
Protection class (DIN EN 60529) IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67
Linearity 10 µm 10 µm 100 µm 100 µm 200 µm 200 µm 25 µm 25 µm 50 µm 50 µm Not specified < ±750…1500 µm
Technical specification details 10 mm net measuring range; 20-30 mm sensor-to-target working window. Not specified 100 mm net measuring range; 50-150 mm sensor-to-target working window. Not specified 200 mm net measuring range; 60-260 mm sensor-to-target working window. Not specified 25 mm net measuring range; 25-50 mm sensor-to-target working window. Not specified Not specified Not specified 500 mm net measuring range; 100-600 mm sensor-to-target working window. Not specified
Measuring rate 2 kHz 2 kHz 2 kHz 2 kHz 2 kHz 2 kHz 2 kHz 2 kHz 2 kHz 2 kHz 2 kHz 2 kHz
Measuring range 10 mm 10 mm 100 mm 100 mm 200 mm 200 mm 25 mm 25 mm 50 mm 50 mm 500 mm 500 mm
Factory-set measuring rate 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz
Contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact
Light spot size on target at mid measuring range 45 × 50 µm 45 × 50 µm (MMR) Not specified 750 × 1100 µm (MMR) Not specified 750 × 1100 µm (MMR) Not specified 55 × 60 µm (MMR) Not specified 80 × 95 µm (MMR) Not specified 750 × 1100 µm (MMR)
Light spot width Y 0.05 mm Not specified 0.91 mm Not specified 0.91 mm Not specified 0.33 mm Not specified 0.095 mm Not specified 0.91 mm Not specified
Light spot width X 0.045 mm Not specified 0.71 mm Not specified 0.71 mm Not specified 0.255 mm Not specified 0.25 mm Not specified 0.71 mm Not specified
Accuracy 10 µm Not specified 100 µm Not specified 200 µm Not specified 25 µm Not specified 50 µm Not specified 1500 µm Not specified
Status Active Active Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — ILD1220-10 (opens in a new tab) PDF — ILD1220-10-IO-Link (opens in a new tab) PDF — ILD1220-100 (opens in a new tab) PDF — ILD1220-100-IO-Link (opens in a new tab) PDF — ILD1220-200 (opens in a new tab) PDF — ILD1220-200-IO-Link (opens in a new tab) PDF — ILD1220-25 (opens in a new tab) PDF — ILD1220-25-IO-Link (opens in a new tab) PDF — ILD1220-50 (opens in a new tab) PDF — ILD1220-50-IO-Link (opens in a new tab) PDF — ILD1220-500 (opens in a new tab) PDF — ILD1220-500-IO-Link (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

Micro-Epsilon specifies a configurable measuring rate up to 2 kHz. Distinguish that capability from the selected operating setting and the data-transfer rate of the complete system.

Its measuring controller is integrated into the sensor. Connection to plant automation can require an interface adapter or IO-Link master according to the sensor version and required interface; these serve a different role from an external measuring controller.

No. Its net span is 10 mm, but the interval is 20–30 mm from the sensor. Match both working interval and installation distance.

The catalogue footnote specifies 1 kHz and median 9. Preserve these conditions and distinguish repeatability from linearity.

Use both dimensions together and state their range position. ILD1220-10 specifies 45×50 µm at mid-range, with different sizes at the start and end.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words