ILD1760-1000
From the optoNCDT 1760-1000 series
optoNCDT 1760-1000: sensors and measurement devices by Micro-Epsilon for laser triangulation.
Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)
Technical specification
Every engineering figure, laid out to scan quickly
| Measuring range | 1000 mm |
|---|---|
| Start of measuring range | 1000 mm |
| End of measuring range | 2000 mm |
| Working distance | 1000–2000 mm |
| Linearity | 1000 µm |
| Repeatability | 100 µm |
| Measuring rate | 7.5 kHz |
| Operating temperature | 0–50 °C |
| Protection class (DIN EN 60529) | IP65 |
| Technical specification details | Measuring range 1000 mm; start/midpoint/end 1000/1500/2000 mm. Ambient-light tolerance 10,000 lx. Sensor mass about 800 g. |
| Accuracy (% FSO) | 0.1 % |
| Linearity reference | Official maximum linearity deviation ±1000 µm, equivalent to ±0.1% FSO. |
| Sampling rate reference | Selectable 7.5, 5, 2.5, 1.25 kHz, 625 Hz and 300 Hz; repeatability is specified at 5 kHz with median 9. |
| Repeatability reference | Official repeatability 100 µm at 5 kHz with median 9. |
| Contact | Non-contact |
Values by configuration
These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.
| Interfaces | EtherCAT |
|---|---|
| Interfaces | EtherNet/IP |
| Interfaces | Ethernet |
| Interfaces | RS422 |
| Interfaces | PROFINET |
| Outputs and interfaces | RS422 / RS485 |
| Outputs and interfaces | Digital I/O |
| Outputs and interfaces | 4-20mA |
| Outputs and interfaces | Analog 0-10V |
The industries we serve
Get a quote or advice
Tell us what you need and an engineer will come back to you.