Skip to content

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for ILD2310-10
Working distance 95–105 mm
Linearity 3 µm
Linearity (% FSO) 0.03 %
Repeatability 0.5 µm
Resolution 0.5 µm
Operating temperature 0–50 °C
Protection class (DIN EN 60529) IP65
Connection plug 14-pin ODU plug
Cable length 0.25 m
Technical specification details Measuring range 10 mm; start/midpoint/end 95/100/105 mm. At 49.14 kHz the usable interval is 5 mm (100-105 mm absolute distance).
Accuracy (% FSO) 0.03 %
Minimum cable bend radius 30 mm
Aluminium housing Aluminum housing
Measurement reference surface The specified data apply to white, diffuse reflecting surfaces (Micro-Epsilon reference ceramic for ILD sensors)
Repeatability reference Official repeatability 0.5 µm under datasheet reference conditions.
Linearity reference Official maximum linearity deviation ±3 µm, equivalent to ±0.03% FSO.
Light spot width Y 0.5 mm
Sampling rate reference Up to 49.14 kHz; the maximum-rate optical interval is 5 mm rather than the full 10 mm range.
Light spot width X 0.4 mm
Contact Non-contact

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

Interfaces Ethernet
Interfaces EtherCAT
Interfaces PROFINET
Measuring range 10 mm
Measuring range 5 mm
Measuring rate 49.14 kHz
Measuring rate 10 kHz
Measuring window 100–105 mm
Measuring window 95–105 mm
Outputs and interfaces 4-20mA
Outputs and interfaces Digital I/O
Outputs and interfaces RS422 / RS485
Outputs and interfaces Analog 0-10V
Request a quote for this product

Compatible accessories

Cables

Complementary products

Accessories

  • SGH size M Exact published sensor/housing fit. Housing rating is separate from the sensor rating; retain cooling requirements for HT.
  • SGHF size M Exact published sensor/housing fit. Housing rating is separate from the sensor rating; retain cooling requirements for HT.
  • SGHF-HT Exact published sensor/housing fit. Housing rating is separate from the sensor rating; retain cooling requirements for HT.

The industries we serve

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words