Technical specification for ILD2310-50
Working distance 550–600 mm
Linearity 50 µm
Linearity (% FSO) 0.1 %
Repeatability 0.5 µm
Resolution 7.5 µm
Operating temperature 0–50 °C
Protection class (DIN EN 60529) IP65
Connection plug 14-pin ODU plug
Cable length 0.25 m
Technical specification details Measuring range 50 mm; start/midpoint/end 550/575/600 mm. At 49.14 kHz the usable interval is 25 mm (575-600 mm absolute distance).
Accuracy (% FSO) 0.1 %
Minimum cable bend radius 30 mm
Aluminium housing Aluminum housing
Measurement reference surface The specified data apply to white, diffuse reflecting surfaces (Micro-Epsilon reference ceramic for ILD sensors)
Repeatability reference Official repeatability 0.5 µm under datasheet reference conditions.
Sampling rate reference Up to 49.14 kHz; the maximum-rate optical interval is 25 mm rather than the full 50 mm range.
Linearity reference Official maximum linearity deviation ±50 µm, equivalent to ±0.1% FSO.
Protective housing compatibility mapping ILD2310-50 is absent from the listed 2310 rows
Contact Non-contact

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

Interfaces PROFINET
Interfaces Ethernet
Interfaces EtherCAT
Measuring range 25 mm
Measuring range 50 mm
Measuring rate 49.14 kHz
Measuring rate 10 kHz
Measuring window 550–600 mm
Measuring window 575–600 mm
Outputs and interfaces Analog 0-10V
Outputs and interfaces 4-20mA
Outputs and interfaces Digital I/O
Outputs and interfaces RS422 / RS485
Request a quote for this product

The industries we serve

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words