Skip to content

optoNCDT Laser Line Laser triangulation

optoNCDT Laser Line: sensors and measurement devices by Micro-Epsilon for laser triangulation.

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of optoNCDT Laser Line
Measuring rate 4000–49140 Hz
Light spot width Y 0.24–1.74 mm
Light spot width X 0.055–0.3 mm
Start of measuring range 15–40 mm
Repeatability 0.1–2 µm
Selectable measuring rates 250–5000 Hz
End of measuring range 17–90 mm
Supply voltage 11–30 V
Measuring range 2–50 mm
Linearity 0.6–40 µm
Power consumption 2–3 W
ADC sampling rate 8000–49140 samples/s
Weight 0.185–0.55 kg
Resolution 0.03–0.8 µm
Measuring window 24–95 mm

Models in the series

One column per model: what differs between the models of the series.

Models of optoNCDT Laser Line compared by parameter
Parameter ILD1420-10LL ILD1420-25LL ILD1420-50LL ILD1900-10LL ILD1900-25LL ILD1900-2LL ILD1900-50LL ILD1900-6LL ILD2300-10LL ILD2300-20LL ILD2300-2LL ILD2300-50LL
Measuring rate 8 kHz 8 kHz 8 kHz 4 kHz 10 kHz 4 kHz 10 kHz 4 kHz 20 kHz 49.14 kHz 49.14 kHz 20 kHz
Light spot width Y 0.635 mm 0.93 mm 1.17 mm 0.73 mm 0.95 mm 0.46 mm 1.74 mm 0.565 mm 0.585 mm 0.485 mm 0.24 mm 0.32 mm
Operating temperature 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C
Light spot width X 0.12 mm 0.2 mm 0.11 mm 0.125 mm 0.21 mm 0.055 mm 0.235 mm 0.1 mm 0.12 mm 0.195 mm 0.064 mm 0.3 mm
Start of measuring range 20 mm 25 mm 35 mm 20 mm 25 mm 15 mm 40 mm 17 mm Not specified Not specified Not specified Not specified
Protection class (DIN EN 60529) IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP65 IP65 IP65 IP65
Repeatability 0.5 µm 1 µm 2 µm 0.4 µm 0.8 µm 0.1 µm 1.6 µm 0.25 µm Not specified Not specified Not specified Not specified
Selectable measuring rates 500 Hz 500 Hz 250 Hz 2 kHz 250 Hz 500 Hz 2 kHz 1 kHz 2.5 kHz 5 kHz 5 kHz 1.5 kHz
End of measuring range 30 mm 50 mm 85 mm 30 mm 50 mm 17 mm 90 mm 23 mm Not specified Not specified Not specified Not specified
Outputs and interfaces RS422 / RS485 RS422 / RS485 Analog 0-10V RS422 / RS485 Analog 0-10V Analog 0-10V Analog 0-10V RS422 / RS485 Analog 0-10V Analog 0-10V RS422 / RS485 RS422 / RS485
Supply voltage 11.2–30 V 11.2–30 V 11.2–30 V 11–30 V 11–30 V 11–30 V 11–30 V 11–30 V 11–30 V 11–30 V 11–30 V 11–30 V
Measuring range 10 mm 25 mm 50 mm 10 mm 25 mm 2 mm 50 mm 6 mm 10 mm 10 mm 2 mm 50 mm
Interfaces Ethernet USB Ethernet USB EtherCAT USB Ethernet Ethernet USB USB Ethernet USB
Linearity 8 µm 20 µm 40 µm 2 µm 5 µm 1 µm 10 µm 1.2 µm 2 µm 4 µm 0.6 µm 10 µm
Laser class Class 2 in accordance with IEC 60825-1:2014 Class 2 in accordance with IEC 60825-1:2014 Class 2 in accordance with IEC 60825-1:2014 Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Storage temperature -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C -20–70 °C
Material Aluminum housing Aluminum housing Aluminum housing Aluminum housing Aluminum housing Aluminum housing Aluminum housing Aluminum housing Die-cast zinc housing Die-cast zinc housing Die-cast zinc housing Die-cast zinc housing
Power consumption 2 W 2 W 2 W 3 W 3 W 3 W 3 W 3 W 3 W 3 W 3 W 3 W
Contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact
ADC sampling rate 8000 samples/s 8000 samples/s 8000 samples/s 10000 samples/s 10000 samples/s 10000 samples/s 10000 samples/s 10000 samples/s 49140 samples/s 49140 samples/s 49140 samples/s 49140 samples/s
Weight Not specified Not specified Not specified 0.3 kg 0.185 kg 0.3 kg 0.185 kg 0.185 kg 0.55 kg 0.55 kg 0.55 kg 0.55 kg
Resolution Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 0.15 µm 0.3 µm 0.03 µm 0.8 µm
Measuring window Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 30–40 mm 50–60 mm 24–26 mm 45–95 mm
Status Active Active Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — ILD1420-10LL (opens in a new tab) PDF — ILD1420-25LL (opens in a new tab) PDF — ILD1420-50LL (opens in a new tab) PDF — ILD1900-10LL (opens in a new tab) PDF — ILD1900-25LL (opens in a new tab) PDF — ILD1900-2LL (opens in a new tab) PDF — ILD1900-50LL (opens in a new tab) PDF — ILD1900-6LL (opens in a new tab) PDF — ILD2300-10LL (opens in a new tab) PDF — ILD2300-20LL (opens in a new tab) PDF — ILD2300-2LL (opens in a new tab) PDF — ILD2300-50LL (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

These versions project a short line for distance measurement on challenging surfaces such as shiny or textured metals. Select the LL platform for the application.

No. LL is an optical variant used across several series. Span, rate and linearity depend on the exact model, not the suffix alone.

No. The table distinguishes start, middle and end. State both spot/line dimensions and the specified working position.

Certain models do. Bracketed spans apply at 49.14 kHz. Check required working coverage against that rate-specific window.

No. Its linearity has specified target conditions. Suitability for challenging surfaces does not remove material, reflectance and angle checks.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words