Skip to content

thicknessCONTROL MTS 8202.K

thicknessCONTROL MTS 8202.K: sensors and measurement devices by Micro-Epsilon for distance & displacement sensors.

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of thicknessCONTROL MTS 8202.K
System accuracy 0.4–2.5 µm
Resolution 0.07–0.36 µm
Repeatability 0.3–2 µm

Models in the series

One column per model: what differs between the models of the series.

Models of thicknessCONTROL MTS 8202.K compared by parameter
Parameter thicknessCONTROL MTS 8202.K-10/1000 thicknessCONTROL MTS 8202.K-10/250 thicknessCONTROL MTS 8202.K-10/500 thicknessCONTROL MTS 8202.K-3/250 thicknessCONTROL MTS 8202.K-3/500 thicknessCONTROL MTS 8202.K-30/1000 thicknessCONTROL MTS 8202.K-30/250 thicknessCONTROL MTS 8202.K-30/500
Operating temperature 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C 5–40 °C
Maximum material width 800 mm 250 mm 500 mm 250 mm 500 mm 800 mm 250 mm 500 mm
Interfaces PROFINET Ethernet PROFINET EtherCAT Ethernet EtherCAT Ethernet PROFINET
Outputs and interfaces Digital I/O Analog 0-10V Digital I/O Digital I/O Digital I/O Digital I/O Analog 0-10V Digital I/O
System accuracy 0.7 µm 0.7 µm 0.7 µm 0.4 µm 0.4 µm 2.5 µm 2.5 µm 2.5 µm
Repeatability reference Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table. Official source value, normally stated at 2 sigma where identified in the family table.
Technical specification details 10 mm thickness measuring range; 800 mm named measuring width; article 4350127.43. 10 mm thickness measuring range; 250 mm named measuring width; article 4350127.41. 10 mm thickness measuring range; 500 mm named measuring width; article 4350127.42. 3 mm thickness measuring range; 250 mm named measuring width; article 4350127.410. 3 mm thickness measuring range; 500 mm named measuring width; article 4350127.411. 30 mm thickness measuring range; 800 mm named measuring width; article 4350127.46. 30 mm thickness measuring range; 250 mm named measuring width; article 4350127.44. 30 mm thickness measuring range; 500 mm named measuring width; article 4350127.45.
Resolution 0.12 µm 0.12 µm 0.12 µm 0.07 µm 0.07 µm 0.36 µm 0.36 µm 0.36 µm
Repeatability 0.5 µm 0.5 µm 0.5 µm 0.3 µm 0.3 µm 2 µm 2 µm 2 µm
Contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact
Status Active Active Active Active Active Active Active Active
Datasheet PDF — thicknessCONTROL MTS 8202.K-10/1000 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.K-10/250 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.K-10/500 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.K-3/250 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.K-3/500 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.K-30/1000 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.K-30/250 (opens in a new tab) PDF — thicknessCONTROL MTS 8202.K-30/500 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

A C-frame with opposed chromatic-confocal sensors for thickness, including suitable shiny surfaces.

No. K identifies the confocal branch. Do not compare it to an LLT scanner’s x-point count.

No. Thickness span, operating gap, pass line and measuring width are distinct. Select the complete system configuration code.

No. Also check tabulated accuracy/repeatability, geometry, material, movement and environment. Small resolution is not a substitute for system accuracy.

Match calibration, sensor positions, motion and control interfaces to the selected configuration. Keep system data separate from head data and on-request options.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words