Skip to content

IF2008/ETH

From the Micro-Epsilon interface and signal-processing accessories series

Micro-Epsilon interface and signal-processing accessories: accessories and system components by Micro-Epsilon for communication adapters.

Visit the Micro-Epsilon site (opens in a new tab)

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for IF2008/ETH
Sensor input interface RS422
Interfaces Ethernet
Network link rate 100 Mbit/s
Supply voltage 11–30 V
Output update rate 200 kHz
Digital inputs 4
Digital outputs 4
Operating temperature 0–50 °C
Humidity 5–95 %RH
Protection class (DIN EN 60529) IP65
Weight 1.7 kg
Measured value transfer protocol Measured value output currently only on TCP server
Material Die-cast aluminum
Interface module configuration notes Module Ethernet data rate is not a guarantee of achieved sensor/controller system rate.
Host-side data interface Ethernet
Internal timers Timers 1 to 3
Sensor or encoder connections 8 x 12-pin sensor/encoder sockets; channels 1-8
Status indicators Ten indicator LEDs
Galvanic isolation no; all GND signals are connected internally and with the housing
Maximum sensor or encoder channels Up to eight sensors and/or encoders with RS422
Reverse polarity protection yes

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

Storage temperature 0–80 °C
Storage temperature 5–50 °C
Request a quote for this product

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It integrates up to eight compatible Micro-Epsilon sensors or encoders with RS422 into an Ethernet network.

Module parameters can be set through its web interface. It also provides four programmable switching I/O and LEDs for device and channel status.

No. The manufacturer lists specific Micro-Epsilon families and models. Check model and protocol compatibility as well as interface type.

No. Its four programmable TTL/HTL switching inputs/outputs are separate from the up to eight sensor or encoder channels.

Ten indicator LEDs show device and channel status. Module parameters are configured through its web interface.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words