Skip to content

Micro-Epsilon protection accessories Protective housings and accessories

Micro-Epsilon protection accessories: accessories and system components by Micro-Epsilon for protective housings and accessories.

Visit the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of Micro-Epsilon protection accessories
Dimension (drawing reference) 25–34 mm
Number of measurement channels 1–6

Models in the series

One column per model: what differs between the models of the series.

Models of Micro-Epsilon protection accessories compared by parameter
Parameter 0323050 0323346 0323349 0755075 0755083 10811916 10812254 2105058 2105059 2105076 2105077 2105079 C2402/Vac/KF16 C2405/Vac/1/CF16 C2405/Vac/1/KF16 C2405/Vac/6/CF63 C5405/VAC/1/CF16 C5405/VAC/1/KF16
Vacuum leak rate limit ≤ 1 × 10^-7 mbar·l·s^-1 ≤ 1 × 10^-9 mbar·l·s^-1 ≤ 1 × 10^-9 mbar·l·s^-1 Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Mounting thread M10x0.75 M9x0.5 Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Dimension (drawing reference) 34 mm 25 mm 25 mm Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Attachment to assembly Not specified Not specified CF16 flange Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified KF16 CF16 KF16 CF63 Not specified Not specified
Number of measurement channels Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 1 1 1 6 Not specified Not specified
Optical connector type Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Vacuum side FC/APC; non-vacuum side E2000/APC FC/APC sockets on both sides FC/APC sockets on both sides FC/APC sockets Not specified Not specified
Status Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — 0323050 (opens in a new tab) PDF — 0323346 (opens in a new tab) PDF — 0323349 (opens in a new tab) PDF — 0755075 (opens in a new tab) PDF — 0755083 (opens in a new tab) PDF — 10811916 (opens in a new tab) PDF — 10812254 (opens in a new tab) PDF — 2105058 (opens in a new tab) PDF — 2105059 (opens in a new tab) PDF — 2105076 (opens in a new tab) PDF — 2105077 (opens in a new tab) PDF — 2105079 (opens in a new tab) PDF — C2402/Vac/KF16 (opens in a new tab) PDF — C2405/Vac/1/CF16 (opens in a new tab) PDF — C2405/Vac/1/KF16 (opens in a new tab) PDF — C2405/Vac/6/CF63 (opens in a new tab) PDF — C5405/VAC/1/CF16 (opens in a new tab) PDF — C5405/VAC/1/KF16 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

The catalogues document housings, protective windows, air purge and cooling for particular configurations. Select them for the sensor model and actual exposure rather than as one universal accessory.

The ILD1900 SGHF arrangement uses air to help clean protective windows and cool the sensor. SGHF-HT configurations use water cooling. Select according to the specific housing’s protection mechanism and requirements.

No. For example, the scanCONTROL 8x00 catalogue distinguishes IP67 from IP40 when active cooling is used. Use the assembled configuration’s rating rather than the bare sensor rating.

No. SGH is described as protecting against water, solvents and detergents, but that does not justify inventing an IP number. Show a numeric code only when documented for the housing and connection configuration.

Preserve the illumination/receiving path and follow the housing’s cleaning and installation instructions. Mechanical fit alone does not establish measurement performance through the window.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words