Skip to content

optoCONTROL 1200

optoCONTROL 1200: sensors and measurement devices by Micro-Epsilon for measurement & 3d systems.

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of optoCONTROL 1200
Resolution 8–30 µm
Accuracy (% FSO) 2–3.5 %
Repeatability 16–60 µm

Models in the series

One column per model: what differs between the models of the series.

Models of optoCONTROL 1200 compared by parameter
Parameter ODC1200-10 ODC1200-16 ODC1200-2 ODC1200-5 ODC1200/90-10 ODC1200/90-16 ODC1200/90-2 ODC1200/90-5
Protection class (DIN EN 60529) IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67
Output update rate 4 kHz 4 kHz 4 kHz 4 kHz 4 kHz 4 kHz 4 kHz 4 kHz
Sampling rate reference 100 kHz measuring rate (-3 dB) at the integrated analog electronics; optional Ethernet/EtherCAT interface module is limited to 14-bit / 4 kSa/s 100 kHz measuring rate (-3 dB) at the integrated analog electronics; optional Ethernet/EtherCAT interface module is limited to 14-bit / 4 kSa/s 100 kHz measuring rate (-3 dB) at the integrated analog electronics; optional Ethernet/EtherCAT interface module is limited to 14-bit / 4 kSa/s 100 kHz measuring rate (-3 dB) at the integrated analog electronics; optional Ethernet/EtherCAT interface module is limited to 14-bit / 4 kSa/s 100 kHz measuring rate (-3 dB) at the integrated analog electronics; optional Ethernet/EtherCAT interface module is limited to 14-bit / 4 kSa/s 100 kHz measuring rate (-3 dB) at the integrated analog electronics; optional Ethernet/EtherCAT interface module is limited to 14-bit / 4 kSa/s 100 kHz measuring rate (-3 dB) at the integrated analog electronics; optional Ethernet/EtherCAT interface module is limited to 14-bit / 4 kSa/s 100 kHz measuring rate (-3 dB) at the integrated analog electronics; optional Ethernet/EtherCAT interface module is limited to 14-bit / 4 kSa/s
Resolution 20 µm 30 µm 8 µm 10 µm 20 µm 30 µm 8 µm 10 µm
Outputs and interfaces Analog 0-10V Digital I/O Analog 0-10V Analog 0-10V Analog 0-10V Analog 0-10V Analog 0-10V Digital I/O
Measuring rate 100 kHz 100 kHz 100 kHz 100 kHz 100 kHz 100 kHz 100 kHz 100 kHz
Interfaces Ethernet Ethernet Ethernet Ethernet Ethernet EtherCAT Ethernet EtherCAT
ADC sampling rate 100000 samples/s 100000 samples/s 100000 samples/s 100000 samples/s 100000 samples/s 100000 samples/s 100000 samples/s 100000 samples/s
Accuracy (% FSO) 2 % 2 % 2 % 2 % 3.5 % 3.5 % 3.5 % 3.5 %
Technical specification details 10 mm measuring range; 20 µm resolution; 40 µm repeatability; axial beam path. 16 mm measuring range; 30 µm resolution; 60 µm repeatability; axial beam path. 2 mm measuring range; 8 µm resolution; 16 µm repeatability; axial beam path. 5 mm measuring range; 10 µm resolution; 20 µm repeatability; axial beam path. 10 mm measuring range; 20 µm resolution; 40 µm repeatability; 90-degree beam path. 16 mm measuring range; 30 µm resolution; 60 µm repeatability; 90-degree beam path. 2 mm measuring range; 8 µm resolution; 16 µm repeatability; 90-degree beam path. 5 mm measuring range; 10 µm resolution; 20 µm repeatability; 90-degree beam path.
Working distance 20–2000 mm 20–2000 mm 20–2000 mm 20–2000 mm 20–2000 mm 20–2000 mm 20–2000 mm 20–2000 mm
Operating temperature 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C 0–50 °C
Repeatability 40 µm 60 µm 16 µm 20 µm 40 µm 60 µm 16 µm 20 µm
Status Active Active Active Active Active Active Active Active
Datasheet PDF — ODC1200-10 (opens in a new tab) PDF — ODC1200-16 (opens in a new tab) PDF — ODC1200-2 (opens in a new tab) PDF — ODC1200-5 (opens in a new tab) PDF — ODC1200/90-10 (opens in a new tab) PDF — ODC1200/90-16 (opens in a new tab) PDF — ODC1200/90-2 (opens in a new tab) PDF — ODC1200/90-5 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

No. Evaluation electronics are integrated; provide appropriate power and connection to the receiving system.

No. The listed separate measuring-range variants are 2, 5, 10, 16, 20 and 30 mm.

No. The manufacturer specifies 100 kHz measurement and up to 60 kHz switching. These are different specifications.

Range alone does not establish accuracy. Read the selected model’s linearity and resolution and verify target coverage.

A measuring output supports evaluation of the measured size; a threshold output changes state at a switching condition. Select the signal type required by the system.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words