Skip to content

MULTIBELT 2 BMP Process industry machines & systems

MULTIBELT 2 BMP: system by Qlar for process industry machines & systems.

This series on the Qlar site (opens in a new tab)

Models in the series

One column per model: what differs between the models of the series.

Models of MULTIBELT 2 BMP compared by parameter
Parameter MULTIBELT 2 BMP 05 MULTIBELT 2 BMP 06 MULTIBELT 2 BMP 08 MULTIBELT 2 BMP 10 MULTIBELT 2 BMP 12 MULTIBELT 2 BMP 14
Linearity reference Series accuracy up to ±0.25% under the documented conveyor and calibration conditions. Series accuracy up to ±0.25% under the documented conveyor and calibration conditions. Series accuracy up to ±0.25% under the documented conveyor and calibration conditions. Series accuracy up to ±0.25% under the documented conveyor and calibration conditions. Series accuracy up to ±0.25% under the documented conveyor and calibration conditions. Series accuracy up to ±0.25% under the documented conveyor and calibration conditions.
Interfaces Ethernet PROFINET Ethernet Ethernet PROFINET Ethernet
Sampling rate reference The weighing controller integrates belt load and belt speed continuously; the official source does not publish one universal raw sample rate for every configuration. The weighing controller integrates belt load and belt speed continuously; the official source does not publish one universal raw sample rate for every configuration. The weighing controller integrates belt load and belt speed continuously; the official source does not publish one universal raw sample rate for every configuration. The weighing controller integrates belt load and belt speed continuously; the official source does not publish one universal raw sample rate for every configuration. The weighing controller integrates belt load and belt speed continuously; the official source does not publish one universal raw sample rate for every configuration. The weighing controller integrates belt load and belt speed continuously; the official source does not publish one universal raw sample rate for every configuration.
Technical specification details 500 mm nominal belt-width ordering code; continuous flow up to 15,000 t/h at series level. 600 mm nominal belt-width ordering code; continuous flow up to 15,000 t/h at series level. 800 mm nominal belt-width ordering code; continuous flow up to 15,000 t/h at series level. 1000 mm nominal belt-width ordering code; continuous flow up to 15,000 t/h at series level. 1200 mm nominal belt-width ordering code; continuous flow up to 15,000 t/h at series level. 1400 mm nominal belt-width ordering code; continuous flow up to 15,000 t/h at series level.
Outputs and interfaces Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O Digital I/O
Repeatability reference Repeatability must be validated with the actual belt, idlers, material loading profile, speed transducer and calibration weights. Repeatability must be validated with the actual belt, idlers, material loading profile, speed transducer and calibration weights. Repeatability must be validated with the actual belt, idlers, material loading profile, speed transducer and calibration weights. Repeatability must be validated with the actual belt, idlers, material loading profile, speed transducer and calibration weights. Repeatability must be validated with the actual belt, idlers, material loading profile, speed transducer and calibration weights. Repeatability must be validated with the actual belt, idlers, material loading profile, speed transducer and calibration weights.
Maximum throughput 15000 t/h 15000 t/h 15000 t/h 15000 t/h 15000 t/h 15000 t/h
Status Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It uses two BMP weighing stations to improve accuracy, as described by the manufacturer.

The English page lists 500–1400 mm and ±0.25% of actual flow, subject to installation and operating conditions.

Up to 15,000 t/h, subject to installation.

Width, speed, inclination, troughing angle, flow and accuracy.

No. Regular weighing-system calibration is recommended.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words