1-P3IC/1000BAR
From the P3IC series
P3IC: sensors and measurement devices by HBK for sensors.
- Pressure reference
- Absolute pressure
Technical specification
Every engineering figure, laid out to scan quickly
| Pressure reference | Absolute pressure |
|---|---|
| Outputs and interfaces | Unknown |
| Operating temperature | -40–100 °C |
| Protection class (DIN EN 60529) | IP67 |
| Technical specification details | 0 to 1000 bar nominal; Absolute pressure; Passive strain gauge; Industrial; Fixed cable |
| Pressure sensor output | Passive strain gauge |
| Sampling rate reference | The selected bridge amplifier and DAQ define the digital sample rate. |
| Pressure measuring principle | Absolute pressure |
| Linearity reference | Official indexed accuracy class: 0.1%. |
| Pressure accuracy class / error | 0.1 % (source basis mandatory) |
| Repeatability reference | No unsupported standalone repeatability is inferred; verify the complete installed pressure chain by calibration. |
| Pressure range | 0–1000 bar |
| Sampling rate limited by system readout | True |
The industries we serve
Get a quote or advice
Tell us what you need and an engineer will come back to you.