Skip to content

1-P60E/100BAR-3

From the P60 series

P60: sensors and measurement devices by HBK for sensors.

Pressure reference
Gauge / relative pressure
Visit the HBK site (opens in a new tab)

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for 1-P60E/100BAR-3
Pressure reference Gauge / relative pressure
Outputs and interfaces Unknown
Operating temperature -40–160 °C
Protection class (DIN EN 60529) IP45
Technical specification details 0 to 100 bar nominal; Relative pressure; Passive strain gauge; Multi purpose; Plug
Repeatability reference No unsupported standalone repeatability is inferred; verify the complete installed pressure chain by calibration.
Sampling rate limited by system readout True
Sampling rate reference The selected bridge amplifier and DAQ define the digital sample rate.
Pressure range 0–100 bar
Pressure accuracy class / error 0.3 % (source basis mandatory)
Pressure measuring principle Relative pressure
Pressure sensor output Passive strain gauge
Linearity reference Official indexed accuracy class: 0.3%.
Request a quote for this product

The industries we serve

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words