PACEline CMC Force

PACEline CMC: sensors and measurement devices by HBK for force.

This series on the HBK site (opens in a new tab)

Models in the series

One column per model: what differs between the models of the series.

Models of PACEline CMC compared by parameter
Parameter PACEline CMC PACEline CMC-120kN PACEline CMC-20kN PACEline CMC-25kN PACEline CMC-50kN PACEline CMC-5kN PACEline CMC-70kN
Outputs and interfaces Unknown Analog 0-10V Analog 0-10V Analog 0-10V Analog 0-10V Analog 0-10V Analog 0-10V
Technical specification details Configurable family; exact public ordering-code table not exposed on the current HBK page. 120 kN rated capacity = 120 kN (12.2366 t mass equivalent at standard gravity); compression 20 kN rated capacity = 20 kN (2.0394 t mass equivalent at standard gravity); compression 25 kN rated capacity = 25 kN (2.5493 t mass equivalent at standard gravity); compression 50 kN rated capacity = 50 kN (5.0986 t mass equivalent at standard gravity); compression 5 kN rated capacity = 5 kN (509.8581 kg mass equivalent at standard gravity); compression 70 kN rated capacity = 70 kN (7.138 t mass equivalent at standard gravity); compression
Force range Not specified 0–120000 N 0–20000 N 0–25000 N 0–50000 N 0–5000 N 0–70000 N
Force range Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Status Active Active Active Active Active Active Active

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

CMC combines a piezoelectric force transducer, cable and charge amplifier. The manufacturer describes chain calibration from force in newtons to voltage, unlike three independently selected components without chain calibration.

The manufacturer specifies a second measurement range with fivefold amplification. This is an amplifier-range selection, not an increase in the head’s permissible force.

The amplifier table documents a ±10 V output. The head’s charge is processed by the amplifier, so acquisition must match the chain output.

No. The table specifies 10 kHz at −3 dB and 5 kHz at −1 dB. These are amplifier frequency-response properties; DAQ sampling rate is separate.

No. The datasheet specifies accuracy class 0.5 for the documented CMC chain. Replacing a cable or amplifier does not establish that the new combination retains its chain calibration and performance.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words