Prewired Strain

Prewired: sensors and measurement devices by HBK for strain.

Visit the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of Prewired
Gauge resistance 350 Ω
Carrier width 4.7–22.9 mm
Carrier length 6.6–18 mm
Grid length 1.5–10 mm
Grid width 1.2–6.5 mm

Models in the series

One column per model: what differs between the models of the series.

Models of Prewired compared by parameter
Parameter 1-LY41-1.5/120V1 1-LY41-10/350V1 1-LY41-3/350V3 1-LY41-6/120V1 1-LY41-6/350V1 1-LY41-6/350V3 1-LY91-1.5/350V3 1-RY81-3/350V1 1-RY81-6/350V1 1-TY11-6/350V1 1-XY41-6/350H3
Gauge resistance 120 Ω 350 Ω 350 Ω 120 Ω 350 Ω 350 Ω 350 Ω 350 Ω 350 Ω 350 Ω 350 Ω
Solder tab or cable connection Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable) Pre-wired (TPE-insulated ribbon cable)
Carrier width 5 mm 8 mm 5.9 mm 5.9 mm 5.9 mm 5.9 mm 4.7 mm 14.6 mm 22.9 mm 18 mm 12.2 mm
Linearity reference Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code.
Technical specification details Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; Linear; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; 3-grid rosette; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; 3-grid rosette; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; T rosette; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable Strain gauge; Shear/torsion; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Pre-wired (TPE-insulated ribbon cable); Bondable
Temperature range (as specified) Standard (up to 200°C) Standard (up to 200°C) Standard (up to 200°C) Standard (up to 200°C) Standard (up to 200°C) Standard (up to 200°C) Standard (up to 200°C) Standard (up to 200°C) Standard (up to 200°C) Standard (up to 200°C) Standard (up to 200°C)
Repeatability reference No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration.
Geometry Linear Linear Linear Linear Linear Linear Linear 3-grid rosette 3-grid rosette T rosette Shear/torsion
Carrier length 7 mm 18 mm 10.9 mm 13.9 mm 13.9 mm 13.9 mm 6.6 mm 9.7 mm 13.1 mm 12 mm 16 mm
Grid length 1.5 mm 10 mm 3 mm 6 mm 6 mm 6 mm 1.5 mm 3 mm 6 mm 6 mm 6 mm
Outputs and interfaces Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown
Grid width 1.2 mm 5 mm 2.5 mm 2.7 mm 2.8 mm 2.8 mm 2 mm 1.2 mm 2.8 mm 6.5 mm 6 mm
Status Active Active Active Active Active Active Active Active Active Active Active

The industries we serve