PW15AH/PW15PH-10kg
From the PW15AH/PW15PH series
PW15AH/PW15PH: sensors and measurement devices by HBK for force.
- Force range
- 0–98.0665 N
Technical specification
Every engineering figure, laid out to scan quickly
| Force range | 0–98.0665 N |
|---|---|
| Operating temperature | -10–50 °C |
| Technical specification details | 10 kg rated capacity = 98.0665 N (10 kg mass equivalent at standard gravity); compression |
Values by configuration
These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.
| ADC sampling rate | 19200 samples/s |
|---|---|
| ADC sampling rate | 40000 samples/s |
| Interfaces | Ethernet |
| Interfaces | IO-Link |
| Interfaces | EtherCAT |
| Interfaces | PROFINET |
| Outputs and interfaces | 4-20mA |
| Outputs and interfaces | Analog 0-10V |
| Outputs and interfaces | Digital I/O |
| Outputs and interfaces | RS422 / RS485 |
| Sampling rate reference | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth |
| Sampling rate reference | LCMC digital update rate is variant- and filter-dependent; confirm it for the ordered chain |
| Sampling rate reference | LCMC measurement-chain update rate is variant- and filter-dependent; confirm it for the ordered chain |
| Sampling rate reference | LCMC analog bandwidth is variant- and filter-dependent; confirm it for the ordered chain |
| Sampling rate reference | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth |
The industries we serve
Get a quote or advice
Tell us what you need and an engineer will come back to you.