Skip to content

K-T210 · 5 N·m · electrical_output=L (IO-Link); rotational_speed_system=3 (IO-Link + speed system)

From the T210 series

T210: sensors and measurement devices by HBK for torque.

Maximum rotational speed
20000 rpm
Selected electrical output
IO-Link

Capacity and selected options are specific to this record. Remaining options: HBK-K-T210-v1

Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for K-T210 · 5 N·m · electrical_output=L (IO-Link); rotational_speed_system=3 (IO-Link + speed system)
Nominal torque capacity 5 Nm
Maximum rotational speed 20000 rpm
Interfaces IO-Link
Selected electrical output IO-Link
Ordering options and constraints K-T210 — capacity: 0.5 N·m, 1 N·m, 2 N·m, 5 N·m, 10 N·m, 20 N·m, 50 N·m, 100 N·m, 200 N·m; size_length: 95 mm (0.5–2 N·m), 145 mm (5–20 N·m), 170 mm (50–200 N·m); accuracy: S; maximum_speed: S; electrical_output: FA (frequency + analog), L (IO-Link); rotational_speed_system: 0 (none), 1 (512 pulses), 2 (1024 pulses), 3 (IO-Link + speed system); custom_modification: N; io_link_firmware: N / IO01 v1.0.0; constraints: [{"when": {"electrical_output": "L (IO-Link)"}, "allow": {"rotational_speed_system": ["0 (none)", "3 (IO-Link + speed system)"]}, "reason": "The T210 ordering data reserves the IO-Link speed-system option for the IO-Link electrical output."}]

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

Selected configuration options accuracy=S;maximum_speed=S;size_length=145 mm (5–20 N·m);electrical_output=L (IO-Link);rotational_speed_system=3 (IO-Link + speed system);custom_modification=N;io_link_firmware=N / IO01 v1.0.0
Selected configuration options 5 N·m nominal torque capacity
Request a quote for this product

Compatible accessories

Cables

  • 1-KAB434-5 Only for source configuration configuration-56124e2112ddbab3f1874aef: K-T210 · 200 N·m configuration · accuracy=S;maximum_speed=S;size_length=170 mm (50–200 N·m);electrical_output=FA (frequency + analog);rotational_speed_system=2 (1024 pulses);custom_modification=N;io_link_firmware=N / IO01 v1.0.0; selected configuration must be matched before display.; For the FA frequency+analog output only, not the L IO-Link version. KAB151A/KAB152 are VK20A junction-box leads, not direct sensor cables. Verify the actual output code and input port before reusing T21WN wiring.
  • 1-KAB435-10 Only for source configuration configuration-56124e2112ddbab3f1874aef: K-T210 · 200 N·m configuration · accuracy=S;maximum_speed=S;size_length=170 mm (50–200 N·m);electrical_output=FA (frequency + analog);rotational_speed_system=2 (1024 pulses);custom_modification=N;io_link_firmware=N / IO01 v1.0.0; selected configuration must be matched before display.; For the FA frequency+analog output only, not the L IO-Link version. KAB151A/KAB152 are VK20A junction-box leads, not direct sensor cables. Verify the actual output code and input port before reusing T21WN wiring.
  • 3-3312.0268 Only for source configuration configuration-56124e2112ddbab3f1874aef: K-T210 · 200 N·m configuration · accuracy=S;maximum_speed=S;size_length=170 mm (50–200 N·m);electrical_output=FA (frequency + analog);rotational_speed_system=2 (1024 pulses);custom_modification=N;io_link_firmware=N / IO01 v1.0.0; selected configuration must be matched before display.; For the FA frequency+analog output only, not the L IO-Link version. KAB151A/KAB152 are VK20A junction-box leads, not direct sensor cables. Verify the actual output code and input port before reusing T21WN wiring.
  • 1-VK20A Only for source configuration configuration-56124e2112ddbab3f1874aef: K-T210 · 200 N·m configuration · accuracy=S;maximum_speed=S;size_length=170 mm (50–200 N·m);electrical_output=FA (frequency + analog);rotational_speed_system=2 (1024 pulses);custom_modification=N;io_link_firmware=N / IO01 v1.0.0; selected configuration must be matched before display.; For the FA frequency+analog output only, not the L IO-Link version. KAB151A/KAB152 are VK20A junction-box leads, not direct sensor cables. Verify the actual output code and input port before reusing T21WN wiring.
  • 1-KAB151A-1.5 Only for source configuration configuration-56124e2112ddbab3f1874aef: K-T210 · 200 N·m configuration · accuracy=S;maximum_speed=S;size_length=170 mm (50–200 N·m);electrical_output=FA (frequency + analog);rotational_speed_system=2 (1024 pulses);custom_modification=N;io_link_firmware=N / IO01 v1.0.0; selected configuration must be matched before display.; For the FA frequency+analog output only, not the L IO-Link version. KAB151A/KAB152 are VK20A junction-box leads, not direct sensor cables. Verify the actual output code and input port before reusing T21WN wiring.
  • 1-KAB152-1.5 Only for source configuration configuration-56124e2112ddbab3f1874aef: K-T210 · 200 N·m configuration · accuracy=S;maximum_speed=S;size_length=170 mm (50–200 N·m);electrical_output=FA (frequency + analog);rotational_speed_system=2 (1024 pulses);custom_modification=N;io_link_firmware=N / IO01 v1.0.0; selected configuration must be matched before display.; For the FA frequency+analog output only, not the L IO-Link version. KAB151A/KAB152 are VK20A junction-box leads, not direct sensor cables. Verify the actual output code and input port before reusing T21WN wiring.

Mounting

  • 1-4413.00xx / K-MBC Only for source configuration configuration-8e760ae93410cae780380c3a: K-T210 · 200 N·m configuration · accuracy=S;maximum_speed=S;size_length=170 mm (50–200 N·m);electrical_output=L (IO-Link);rotational_speed_system=3 (IO-Link + speed system);custom_modification=N;io_link_firmware=N / IO01 v1.0.0; selected configuration must be matched before display.; Select both bore diameters, rated torque, speed, allowable misalignment and moment of inertia. D1 is selected for the transducer side and D2 for the drive shaft; this family placeholder is not an orderable final coupling code.

The industries we serve

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words