Range across the models of thermoMETER FI
Cable length 1–15 m
Temperature measuring range -40–1100 °C

Models in the series

One column per model: what differs between the models of the series.

Models of thermoMETER FI compared by parameter
Parameter FI-SF15-C1 FI-SF15-C15 FI-SF15-C3 FI-SF15-C8
Supply voltage 5–30 V 5–30 V 5–30 V 5–30 V
Cable length 1 m 15 m 3 m 8 m
Temperature repeatability 0.75 K 0.75 K 0.75 K 0.75 K
Spectral range 8000–14000 nm 8000–14000 nm 8000–14000 nm 8000–14000 nm
Interfaces USB USB USB USB
Protection class (DIN EN 60529) IP65 IP63 IP63 IP65
Humidity 10–95 %RH 10–95 %RH 10–95 %RH 10–95 %RH
Temperature measuring range -40–1100 °C -40–1100 °C -40–600 °C -40–600 °C
Temperature repeatability (of reading) 0.75 % 0.75 % 0.75 % 0.75 %
Outputs and interfaces Analog 0-10V Analog 0-10V Digital I/O Analog 0-10V
ADC sampling rate 50 samples/s 50 samples/s 50 samples/s 50 samples/s
Weight 0.06 kg 0.06 kg 0.06 kg 0.06 kg
Temperature accuracy 1.5 K 1.5 K 1.5 K 1.5 K
NETD 50 mK 50 mK 50 mK 50 mK
Storage temperature -40–85 °C -40–85 °C -40–85 °C -40–85 °C
Operating temperature -20–80 °C -20–80 °C -20–80 °C -20–80 °C
Current consumption 6 mA 6 mA 6 mA 6 mA
Temperature accuracy (% of reading) 1.5 % 1.5 % 1.5 % 1.5 %
Technical specification details Not specified Not specified -40 to +600 C standard, optional extension to 1100 C; 15:1 optics; ±0.75% or ±0.75 C repeatability; 50 mK NETD. Not specified
Sampling rate reference Not specified Not specified 20 ms 0-90% response time (50 Hz equivalent) Not specified
Linearity reference Not specified Not specified Micro-Epsilon specifies system accuracy, repeatability and NETD; a separate linearity error is not published. Not specified
Status Active Active Active Active
Datasheet PDF — FI-SF15-C1 (opens in a new tab) PDF — FI-SF15-C15 (opens in a new tab) PDF — FI-SF15-C8 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

No. Sensor and controller share one stainless-steel housing. An optional USB converter and sensorTOOL provide extended configuration.

No. Its stated measurement range is −40 to +1100°C, while the factory preset is 0 to +600°C. Configure it for the application.

The page specifies up to 80°C without cooling. This is an instrument ambient limit, separate from target-temperature range.

Yes. It specifies parallel analog/digital operation and a 200 mA open-collector output. Match wiring and output configuration to the control system.

It provides an alignment aid and red/green status LEDs for alarms or system state. Advanced settings use the optional USB converter and sensorTOOL.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words