Skip to content

K-U10M · 1.25 MN

From the U10M series

U10M: sensors and measurement devices by HBK for force.

Capacity and selected options are specific to this record. Remaining options: HBK-K-U10M-v1

Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for K-U10M · 1.25 MN
Nominal force capacity 1250000 N
Ordering options and constraints K-U10M — capacity: 1.25 kN, 2.5 kN, 5 kN, 12.5 kN, 25 kN, 50 kN, 125 kN, 250 kN, 500 kN, 1.25 MN; bridge: SB, DB; rated_output: N, J; calibration: 100%, 200%; teds: Not selected, T; mechanical_design: W adapter, N flange; plug_protection: P, U; electrical_connection: B, G, K (6 m), V (15 m), 00A4 (VAIO); force_application: O, L; cable_plug: Y, F, Q, N, P, M, X; integrated_amplifier: N, VAIO; constraints: [{"when": {"teds": "T"}, "deny": {"integrated_amplifier": ["VAIO"]}, "reason": "TEDS and the integrated VAIO amplifier are mutually exclusive in the official configuration."}, {"when": {"integrated_amplifier": "VAIO"}, "allow": {"electrical_connection": "00A4 (VAIO)"}, "reason": "The VAIO connection is reserved for the integrated-amplifier option."}]
Selected configuration options 1.25 MN nominal force capacity
Request a quote for this product

Compatible accessories

Cables

  • K-CAB-F-B Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
  • K-CAB-F-G Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
  • K-CAB-F-L Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
  • 1-KAB157-3 Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; The threaded cable is rated differently in U10M and C10 documents; do not assign a universal IP class. Check socket, locked connector and end wiring.
  • 1-KAB158-3 Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; The threaded cable is rated differently in U10M and C10 documents; do not assign a universal IP class. Check socket, locked connector and end wiring.
  • 1-CON/BS1 Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; BS1: cable Ø4–6.5 mm; BS2: Ø≥6.5 mm. Match bayonet/threaded sensor connection, sealing and wiring.
  • 1-CON/BS2 Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; BS1: cable Ø4–6.5 mm; BS2: Ø≥6.5 mm. Match bayonet/threaded sensor connection, sealing and wiring.
  • 3-3312.0354 Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; BS1: cable Ø4–6.5 mm; BS2: Ø≥6.5 mm. Match bayonet/threaded sensor connection, sealing and wiring.
  • 1-EEK4 Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; Grounding accessory, not a measurement-signal cable.
  • 1-EEK6 Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; Grounding accessory, not a measurement-signal cable.
  • 1-EEK8 Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; Grounding accessory, not a measurement-signal cable.

Mounting

  • 1-Z4/20kN/ZGUW Only for source configuration configuration-cce1231401650668f78fdaf0: K-U10M · 25 kN configuration; selected configuration must be matched before display.; Static tensile loading only; not compression or fatigue qualification. Verify exact rated capacity and thread.
  • 1-ZGAM33F Only for source configuration configuration-52726999a6594ecf17183d30: K-U10M · 125 kN configuration; selected configuration must be matched before display.; Static tensile loading only; not compression or fatigue qualification. Verify exact rated capacity and thread.
  • 1-ZGAM42F Only for source configuration configuration-dbde2ddaacceafe597ecc6de: K-U10M · 250 kN configuration; selected configuration must be matched before display.; Static tensile loading only; not compression or fatigue qualification. Verify exact rated capacity and thread.
  • 1-ZGAM72F Only for source configuration configuration-28d0babd11da16791c108ede: K-U10M · 500 kN configuration; selected configuration must be matched before display.; Static tensile loading only; not compression or fatigue qualification. Verify exact rated capacity and thread.

The industries we serve

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words