K-U10M · 125 kN
From the U10M series
U10M: sensors and measurement devices by HBK for force.
Capacity and selected options are specific to this record. Remaining options: HBK-K-U10M-v1
Download the datasheet (opens in a new tab) This series on the HBK site (opens in a new tab)
Technical specification
Every engineering figure, laid out to scan quickly
| Nominal force capacity | 125000 N |
|---|---|
| Ordering options and constraints | K-U10M — capacity: 1.25 kN, 2.5 kN, 5 kN, 12.5 kN, 25 kN, 50 kN, 125 kN, 250 kN, 500 kN, 1.25 MN; bridge: SB, DB; rated_output: N, J; calibration: 100%, 200%; teds: Not selected, T; mechanical_design: W adapter, N flange; plug_protection: P, U; electrical_connection: B, G, K (6 m), V (15 m), 00A4 (VAIO); force_application: O, L; cable_plug: Y, F, Q, N, P, M, X; integrated_amplifier: N, VAIO; constraints: [{"when": {"teds": "T"}, "deny": {"integrated_amplifier": ["VAIO"]}, "reason": "TEDS and the integrated VAIO amplifier are mutually exclusive in the official configuration."}, {"when": {"integrated_amplifier": "VAIO"}, "allow": {"electrical_connection": "00A4 (VAIO)"}, "reason": "The VAIO connection is reserved for the integrated-amplifier option."}] |
| Selected configuration options | 125 kN nominal force capacity |
Compatible accessories
Cables
-
K-CAB-F-B
Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
-
K-CAB-F-G
Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
-
K-CAB-F-L
Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; Only for the listed passive SG sensor socket; fixed-cable K/V and VAIO/4-pin IO-Link are excluded. Select the amplifier end and validate carrier-frequency precision, EMC and calibration with the cable length.; 0131: static/dynamic bend radius 22/50 mm, -50…80 °C, 280 Ω/km; high-precision use may require low carrier frequency and stable temperature. 0157: 37/75 mm, -50…85 °C, 78 Ω/km. 139B: 75 mm static, no drag chain; -30…70 °C stationary / -5…50 °C moving; incompatible with P/M ends.; IP protection depends on the actual sensor socket, seal and connector locking; a generic connector IP rating is not the assembled sensor IP rating.
-
1-KAB157-3
Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; The threaded cable is rated differently in U10M and C10 documents; do not assign a universal IP class. Check socket, locked connector and end wiring.
-
1-KAB158-3
Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; The threaded cable is rated differently in U10M and C10 documents; do not assign a universal IP class. Check socket, locked connector and end wiring.
-
1-CON/BS1
Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; BS1: cable Ø4–6.5 mm; BS2: Ø≥6.5 mm. Match bayonet/threaded sensor connection, sealing and wiring.
-
1-CON/BS2
Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; BS1: cable Ø4–6.5 mm; BS2: Ø≥6.5 mm. Match bayonet/threaded sensor connection, sealing and wiring.
-
3-3312.0354
Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; BS1: cable Ø4–6.5 mm; BS2: Ø≥6.5 mm. Match bayonet/threaded sensor connection, sealing and wiring.
-
1-EEK4
Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; Grounding accessory, not a measurement-signal cable.
-
1-EEK6
Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; Grounding accessory, not a measurement-signal cable.
-
1-EEK8
Only for source configuration configuration-f9ea1f13fa3a9856b15a30a5: K-U10M · 1.25 MN configuration; selected configuration must be matched before display.; Grounding accessory, not a measurement-signal cable.
Mounting
-
1-Z4/20kN/ZGUW
Only for source configuration configuration-cce1231401650668f78fdaf0: K-U10M · 25 kN configuration; selected configuration must be matched before display.; Static tensile loading only; not compression or fatigue qualification. Verify exact rated capacity and thread.
-
1-ZGAM33F
Only for source configuration configuration-52726999a6594ecf17183d30: K-U10M · 125 kN configuration; selected configuration must be matched before display.; Static tensile loading only; not compression or fatigue qualification. Verify exact rated capacity and thread.
-
1-ZGAM42F
Only for source configuration configuration-dbde2ddaacceafe597ecc6de: K-U10M · 250 kN configuration; selected configuration must be matched before display.; Static tensile loading only; not compression or fatigue qualification. Verify exact rated capacity and thread.
-
1-ZGAM72F
Only for source configuration configuration-28d0babd11da16791c108ede: K-U10M · 500 kN configuration; selected configuration must be matched before display.; Static tensile loading only; not compression or fatigue qualification. Verify exact rated capacity and thread.
The industries we serve
Get a quote or advice
Tell us what you need and an engineer will come back to you.