Skip to content

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Technical specification for U93A
Ordering options and constraints K-U93A — capacity: 224.81 lbf, 449.62 lbf, 1124.04 lbf, 2248.09 lbf, 4496.18 lbf, 11240.05 lbf; output_signal: mV/V (passive strain gauge), Current (4-20mA), Voltage (0…10V), IO-Link; height_without_accessories: 1.89 in, 1.2 in; diameter_without_cable_or_plug: 1.65 in, 1.02 in; constraints: []

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of U93A
Interfaces IO-Link
Force range 0–50000 N
Nominal force capacity 1000–50000 N

Models in the series

One column per model: what differs between the models of the series.

Models of U93A compared by parameter
Parameter 1-U93A/10KN 1-U93A/1KN 1-U93A/20KN 1-U93A/2KN 1-U93A/50KN 1-U93A/5KN K-U93A · 1 kN K-U93A · 10 kN K-U93A · 2 kN K-U93A · 20 kN K-U93A · 5 kN K-U93A · 50 kN U93A-10kN U93A-1kN U93A-20kN U93A-2kN U93A-50kN U93A-5kN
Interfaces Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified IO-Link IO-Link EtherCAT Ethernet Ethernet PROFINET
Force range 0–10000 N 0–1000 N 0–20000 N 0–2000 N 0–50000 N 0–5000 N Not specified Not specified Not specified Not specified Not specified Not specified -10000–10000 N -1000–1000 N -20000–20000 N -2000–2000 N -50000–50000 N -5000–5000 N
Force range Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Technical specification details Maximum capacity (nominal load): 2248.1 lbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.2 in; Diameter (without cable or plug): 1.02 in Maximum capacity (nominal load): 224.81 lbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.2 in; Diameter (without cable or plug): 1.02 in Maximum capacity (nominal load): 1124.04 lbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.89 in; Diameter (without cable or plug): 1.65 in Maximum capacity (nominal load): 449.62 lbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.2 in; Diameter (without cable or plug): 1.02 in Maximum capacity (nominal load): 11240.45 lbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.89 in; Diameter (without cable or plug): 1.65 in Maximum capacity (nominal load): 1124.04 lbf; Output signal: mV/V (passive strain gauge); Height (without accessories): 1.2 in; Diameter (without cable or plug): 1.02 in Not specified Not specified Not specified Not specified Not specified Not specified 10 kN rated capacity = 10 kN (1.0197 t mass equivalent at standard gravity); compression and tension 1 kN rated capacity = 1 kN (101.9716 kg mass equivalent at standard gravity); compression and tension 20 kN rated capacity = 20 kN (2.0394 t mass equivalent at standard gravity); compression and tension 2 kN rated capacity = 2 kN (203.9432 kg mass equivalent at standard gravity); compression and tension 50 kN rated capacity = 50 kN (5.0986 t mass equivalent at standard gravity); compression and tension 5 kN rated capacity = 5 kN (509.8581 kg mass equivalent at standard gravity); compression and tension
Outputs and interfaces Unknown Unknown Unknown Unknown Unknown Unknown Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Selected configuration options Not specified Not specified Not specified Not specified Not specified Not specified 1 kN nominal force capacity 10 kN nominal force capacity 2 kN nominal force capacity 20 kN nominal force capacity 5 kN nominal force capacity 50 kN nominal force capacity Not specified Not specified Not specified Not specified Not specified Not specified
Nominal force capacity Not specified Not specified Not specified Not specified Not specified Not specified 1000 N 10000 N 2000 N 20000 N 5000 N 50000 N Not specified Not specified Not specified Not specified Not specified Not specified
ADC sampling rate Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 1111 samples/s 1111 samples/s 1111 samples/s 1111 samples/s 1111 samples/s 1111 samples/s
Accuracy (% FSO) Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 0.2 % 0.2 % 0.2 % 0.2 % 0.2 % 0.2 %
Status Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — K-U93A · 1 kN (opens in a new tab) PDF — K-U93A · 10 kN (opens in a new tab) PDF — K-U93A · 2 kN (opens in a new tab) PDF — K-U93A · 20 kN (opens in a new tab) PDF — K-U93A · 5 kN (opens in a new tab) PDF — K-U93A · 50 kN (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

U93A measures axial tensile and compressive force, including alternating loads. Install it through the flanges on both sides in accordance with HBM's mounting instructions.

HBM's datasheet specifies IP68 with a test condition of 1 m water depth for 100 hours. This does not establish suitability for every depth, duration or installation condition.

No. The drawing distinguishes the 1–10 kN group from 20–50 kN. Select the mounting arrangement and screws for the exact group and capacity.

No. The permanently connected amplifier and 4–20 mA, 0–10 V or IO-Link outputs are ordering options. Associate the output with the selected configuration code.

It is the transducer’s accuracy class, not a claim that every installed measurement chain has the same uncertainty. Select the corresponding amplifier and force-introduction accessories.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words