Range across models
The span covered by the models of the series together — not the range of each model.
| Gauge resistance | 120–350 Ω |
|---|---|
| Maximum excitation voltage | 3.5–13 V |
| Dimension (drawing reference) | 1.3–23 mm |
| Grid width | 1.3–15 mm |
| Grid length | 3–15 mm |
| Carrier length | 7.3–23 mm |
| Carrier width | 7.3–23 mm |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 1-MY21-15/350 | 1-MY21-6/120 | 1-MY23-15/350 | 1-MY23-6/120 | 1-MY25-15/350 | 1-MY25-6/120 | 1-MY26-15/350 | 1-MY26-6/120 | 1-MY27-15/350 | 1-MY27-6/120 | 1-MY28-15/350 | 1-MY28-6/120 | 1-VY11-3/120 | 1-VY11-6/120 | 1-VY13-3/120 | 1-VY13-6/120 | 1-VY15-3/120 | 1-VY15-6/120 | 1-VY16-3/120 | 1-VY16-6/120 | 1-VY17-3/120 | 1-VY17-6/120 | 1-VY18-3/120 | 1-VY18-6/120 | 1-VY41-3/120 | 1-VY41-3/350 | 1-VY41-6/120 | 1-VY41-6/350 | 1-VY43-3/120 | 1-VY43-3/350 | 1-VY43-6/120 | 1-VY43-6/350 | 1-VY45-3/120 | 1-VY45-3/350 | 1-VY45-6/120 | 1-VY45-6/350 | 1-VY46-3/120 | 1-VY46-3/350 | 1-VY46-6/120 | 1-VY46-6/350 | 1-VY47-3/120 | 1-VY47-3/350 | 1-VY47-6/120 | 1-VY47-6/350 | 1-VY48-3/120 | 1-VY48-3/350 | 1-VY48-6/120 | 1-VY48-6/350 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Gauge resistance | 350 Ω | 120 Ω | 350 Ω | 120 Ω | 350 Ω | 120 Ω | 350 Ω | 120 Ω | 350 Ω | 120 Ω | 350 Ω | 120 Ω | 120 Ω | 120 Ω | 120 Ω | 120 Ω | 120 Ω | 120 Ω | 120 Ω | 120 Ω | 120 Ω | 120 Ω | 120 Ω | 120 Ω | 120 Ω | 350 Ω | 120 Ω | 350 Ω | 120 Ω | 350 Ω | 120 Ω | 350 Ω | 120 Ω | 350 Ω | 120 Ω | 350 Ω | 120 Ω | 350 Ω | 120 Ω | 350 Ω | 120 Ω | 350 Ω | 120 Ω | 350 Ω | 120 Ω | 350 Ω | 120 Ω | 350 Ω |
| Outputs and interfaces | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown | Unknown |
| Solder tab or cable connection | Leads | Leads | Leads | Leads | Leads | Leads | Leads | LS 7 | Leads | LS 7 | LS 5 | Leads | LS 5/7 | Leads | Leads | Leads | Leads | LS 5/7 | LS 5/7 | Leads | Leads | Leads | Leads | LS 5/7 | Integrated solder tabs | LS7 | Integrated solder tabs | Integrated solder tabs | Integrated solder tabs | LS7 | Integrated solder tabs | Integrated solder tabs | LS7 | Integrated solder tabs | Integrated solder tabs | LS4 | Integrated solder tabs | LS7 | LS4 | Integrated solder tabs | LS7 | LS7 | LS4 | Integrated solder tabs | LS7 | LS7 | LS4 | Integrated solder tabs |
| Maximum excitation voltage | 13 V | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 6 V | 12 V | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | 3.5 V | 6 V | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified | Not specified |
| Repeatability reference | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. | No unsupported standalone repeatability is inferred; installed repeatability is verified after bonding and shunt calibration. |
| Geometry | Diaphragm rosette | Diaphragm rosette | Diaphragm rosette | Diaphragm rosette | Diaphragm rosette | Diaphragm rosette | Diaphragm rosette | Diaphragm rosette | Diaphragm rosette | Diaphragm rosette | Diaphragm rosette | Diaphragm rosette | 0°/90° T full bridge | 0°/90° T full bridge | 0°/90° T full bridge | 0°/90° T full bridge | 0°/90° T full bridge | 0°/90° T full bridge | 0°/90° T full bridge | 0°/90° T full bridge | 0°/90° T full bridge | 0°/90° T full bridge | 0°/90° T full bridge | 0°/90° T full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge | Shear/torsion full bridge |
| Dimension (drawing reference) | 17 mm | Not specified | Not specified | Not specified | 17 mm | 6 mm | 15 mm | 6 mm | 17 mm | 6 mm | 15 mm | 7.3 mm | 13.5 mm | 23 mm | Not specified | Not specified | 7 mm | 6 mm | 3 mm | 23 mm | 3 mm | 6 mm | 7 mm | 23 mm | 3 mm | 3 mm | Not specified | Not specified | Not specified | 9.8 mm | Not specified | Not specified | 10 mm | 10 mm | 18 mm | 17 mm | 1.3 mm | 1.3 mm | 6 mm | 2.7 mm | 1.3 mm | 9.8 mm | 17 mm | 2.7 mm | 9.8 mm | 9.8 mm | 18 mm | 6 mm |
| Grid width | 15 mm | 6 mm | 15 mm | 6 mm | 15 mm | 6 mm | 15 mm | 6 mm | 15 mm | 6 mm | 15 mm | 6 mm | 7 mm | 14 mm | 7 mm | 14 mm | 7 mm | 14 mm | 7 mm | 14 mm | 7 mm | 14 mm | 7 mm | 14 mm | 1.3 mm | 1.3 mm | 2.7 mm | 2.7 mm | 1.3 mm | 1.3 mm | 2.7 mm | 2.7 mm | 1.3 mm | 1.3 mm | 2.7 mm | 2.7 mm | 1.3 mm | 1.3 mm | 2.7 mm | 2.7 mm | 1.3 mm | 1.3 mm | 2.7 mm | 2.7 mm | 1.3 mm | 1.3 mm | 2.7 mm | 2.7 mm |
| Grid length | 15 mm | 6 mm | 15 mm | 6 mm | 15 mm | 6 mm | 15 mm | 6 mm | 15 mm | 6 mm | 15 mm | 6 mm | 3 mm | 6 mm | 3 mm | 6 mm | 3 mm | 6 mm | 3 mm | 6 mm | 3 mm | 6 mm | 3 mm | 6 mm | 3 mm | 3 mm | 6 mm | 6 mm | 3 mm | 3 mm | 6 mm | 6 mm | 3 mm | 3 mm | 6 mm | 6 mm | 3 mm | 3 mm | 6 mm | 6 mm | 3 mm | 3 mm | 6 mm | 6 mm | 3 mm | 3 mm | 6 mm | 6 mm |
| Pieces per package | 5 | Not specified | Not specified | Not specified | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | Not specified | Not specified | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | Not specified | Not specified | Not specified | 5 | Not specified | Not specified | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
| Linearity reference | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. | Use the exact HBK gauge factor, transverse sensitivity and batch calibration values supplied with the ordering code. |
| Technical specification details | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Aluminium (23 ppm/K; 12.8 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Aluminium (23 ppm/K; 12.8 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Austenitic steel (16 ppm/K; 8.9 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Austenitic steel (16 ppm/K; 8.9 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Silica / composite (0,5 ppm/K; 0.3 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Silica / composite (0,5 ppm/K; 0.3 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Titanium / gray cast iron (9 ppm/K; 5.0 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Titanium / gray cast iron (9 ppm/K; 5.0 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Plastic (65 ppm/K; 36.1 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Plastic (65 ppm/K; 36.1 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Aluminium (23 ppm/K; 12.8 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Aluminium (23 ppm/K; 12.8 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Austenitic steel (16 ppm/K; 8.9 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Austenitic steel (16 ppm/K; 8.9 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Silica / composite (0,5 ppm/K; 0.3 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Silica / composite (0,5 ppm/K; 0.3 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Titanium / gray cast iron (9 ppm/K; 5.0 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Titanium / gray cast iron (9 ppm/K; 5.0 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Plastic (65 ppm/K; 36.1 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Plastic (65 ppm/K; 36.1 ppm/°F); Leads; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Ferritic steel (10.8 ppm/K; 6.0 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Aluminium (23 ppm/K; 12.8 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Aluminium (23 ppm/K; 12.8 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Aluminium (23 ppm/K; 12.8 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Aluminium (23 ppm/K; 12.8 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Austenitic steel (16 ppm/K; 8.9 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Austenitic steel (16 ppm/K; 8.9 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Austenitic steel (16 ppm/K; 8.9 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Austenitic steel (16 ppm/K; 8.9 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Silica / composite (0,5 ppm/K; 0.3 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Silica / composite (0,5 ppm/K; 0.3 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Silica / composite (0,5 ppm/K; 0.3 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Silica / composite (0,5 ppm/K; 0.3 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Titanium / gray cast iron (9 ppm/K; 5.0 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Titanium / gray cast iron (9 ppm/K; 5.0 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Titanium / gray cast iron (9 ppm/K; 5.0 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Titanium / gray cast iron (9 ppm/K; 5.0 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Plastic (65 ppm/K; 36.1 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Plastic (65 ppm/K; 36.1 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Plastic (65 ppm/K; 36.1 ppm/°F); Integrated solder tabs; Bondable | Strain gauge; Full bridge circuit; Constantan (ca 2.0); Standard (up to 200°C); Plastic (65 ppm/K; 36.1 ppm/°F); Integrated solder tabs; Bondable |
| Carrier length | 17 mm | 7.3 mm | 17 mm | 7.3 mm | 17 mm | 7.3 mm | 17 mm | 7.3 mm | 17 mm | 7.3 mm | 17 mm | 7.3 mm | 13.5 mm | 23 mm | 13.5 mm | 23 mm | 13.5 mm | 23 mm | 13.5 mm | 23 mm | 13.5 mm | 23 mm | 13.5 mm | 23 mm | 9.8 mm | 9.8 mm | 18 mm | 18 mm | 9.8 mm | 9.8 mm | 18 mm | 18 mm | 9.8 mm | 9.8 mm | 18 mm | 18 mm | 9.8 mm | 9.8 mm | 18 mm | 18 mm | 9.8 mm | 9.8 mm | 18 mm | 18 mm | 9.8 mm | 9.8 mm | 18 mm | 18 mm |
| Carrier width | 17 mm | 7.3 mm | 17 mm | 7.3 mm | 17 mm | 7.3 mm | 17 mm | 7.3 mm | 17 mm | 7.3 mm | 17 mm | 7.3 mm | 13.5 mm | 23 mm | 13.5 mm | 23 mm | 13.5 mm | 23 mm | 13.5 mm | 23 mm | 13.5 mm | 23 mm | 13.5 mm | 23 mm | 10 mm | 10 mm | 17 mm | 17 mm | 10 mm | 10 mm | 17 mm | 17 mm | 10 mm | 10 mm | 17 mm | 17 mm | 10 mm | 10 mm | 17 mm | 17 mm | 10 mm | 10 mm | 17 mm | 17 mm | 10 mm | 10 mm | 17 mm | 17 mm |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |