Skip to content

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Technical specification for Z16A
Ordering options and constraints K-Z16A3 — type: Shear beam (canister); capacity: 16530 lb; accuracy_class: D1, C3; minimum_verification_interval_vmin: 1500 g, 3000 g, 4000 g; constraints: []

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of Z16A
Force range 0–73529.1033 N
Accuracy (% FSO) 1–3 %

Models in the series

One column per model: what differs between the models of the series.

Models of Z16A compared by parameter
Parameter 1-Z16A3C3/15T 1-Z16A3D1/15T 1-Z16A3D1/7.5T K-Z16A3 · 16530 lb
Force range 0–147099.75 N 0–147099.75 N 0–73549.875 N Not specified
Force range Not specified Not specified Not specified Not specified
Technical specification details Type: S-type / tension; Maximum capacity: 33060 lb; Accuracy class: C3; Minimum verification interval (Vmin): 1500 g Type: S-type / tension; Maximum capacity: 33060 lb; Accuracy class: D1; Minimum verification interval (Vmin): 3000 g Type: S-type / tension; Maximum capacity: 16530 lb; Accuracy class: D1; Minimum verification interval (Vmin): 1500 g Not specified
Outputs and interfaces Unknown Unknown Unknown Not specified
Accuracy (% FSO) 3 % 1 % 1 % Not specified
Selected configuration options Not specified Not specified Not specified 16530 lb nominal force capacity
Nominal force capacity Not specified Not specified Not specified 73529.1033 N
Published accuracy class Not specified Not specified Not specified Official family-table accuracy class: D1, C3
Status Active Active Active Active
Datasheet PDF — K-Z16A3 · 16530 lb (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

Tension weighing of suspended loads.

The table lists 7.5 t as D1; C3 is specified for 15 t.

A six-wire analogue bridge.

IP68 and IP69K under the documented test conditions.

No. Explosion protection is an ordered option with specific zones and protection types.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words