Z6-500kg
From the Z6 series
Z6: sensors and measurement devices by HBK for force.
- Force range
- 0–4903.325 N
Technical specification
Every engineering figure, laid out to scan quickly
| Force range | 0–4903.325 N |
|---|---|
| Operating temperature | -30–70 °C |
| Protection class (DIN EN 60529) | IP68 |
| Technical specification details | 500 kg rated capacity = 4.9033 kN (500 kg mass equivalent at standard gravity); compression |
| Ordering options and constraints | K-Z6- — application: Animal Weighing (Lifestock), Checkweighing, Dynamic Filling / Dosing, Static Filling/Dosing, Silo/Tank weighing; capacity: 11.02 lb, 22.04 lb, 44.09 lb, 66.14 lb, 110.23 lb, 220.46 lb, 440.92 lb, 1102.31 lb, 2204.62 lb; accuracy_class: C3, C4, C6, D1; minimum_verification_interval_vmin: 90 g, 0.9 g, 1.8 g, 2.49 g, 4.5 g, 9 g, 18 g, 45 g, 1.32 g, 1.98 g, 3.3 g, 6.6 g, 13.2 g, 33 g, 1.8 g, 3.6 g, 7.2 g, 10.8 g, 18 GRM, 36 g, 72 g, 180 g, 360 g; certification: OIML, NTEP (US), ATEX/IECEx; special_feature: None; constraints: [] |
Values by configuration
These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.
| ADC sampling rate | 19200 samples/s |
|---|---|
| ADC sampling rate | 40000 samples/s |
| Interfaces | Ethernet |
| Interfaces | EtherCAT |
| Interfaces | PROFINET |
| Interfaces | IO-Link |
| Outputs and interfaces | 4-20mA |
| Outputs and interfaces | Analog 0-10V |
| Outputs and interfaces | Digital I/O |
| Outputs and interfaces | RS422 / RS485 |
| Sampling rate reference | MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth |
| Sampling rate reference | LCMC analog bandwidth is variant- and filter-dependent; confirm it for the ordered chain |
| Sampling rate reference | LCMC measurement-chain update rate is variant- and filter-dependent; confirm it for the ordered chain |
| Sampling rate reference | ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth |
| Sampling rate reference | LCMC digital update rate is variant- and filter-dependent; confirm it for the ordered chain |
The industries we serve
Get a quote or advice
Tell us what you need and an engineer will come back to you.