Skip to content

ASA-068 Ex accelerometer cable-length variants

ASA-068 Ex accelerometer cable-length variants: sensors and measurement devices by Brüel & Kjær Vibro for vibration.

Download the datasheet (opens in a new tab) This series on the Brüel & Kjær Vibro site (opens in a new tab)

Models in the series

One column per model: what differs between the models of the series.

Models of ASA-068 Ex accelerometer cable-length variants compared by parameter
Parameter ASA-068/050/0 ASA-068/100/0 ASA-068/150/0 ASA-068/200/0 ASA-068/250/0 ASA-068/300/0 ASA-068/350/0 ASA-068/400/0 ASA-068/450/0 ASA-068/500/0
Frequency response 1.5–13000 Hz 1.5–13000 Hz 1.5–13000 Hz 1.5–13000 Hz 1.5–13000 Hz 1.5–13000 Hz 1.5–13000 Hz 1.5–13000 Hz 1.5–13000 Hz 1.5–13000 Hz
Operating temperature -50–125 °C -50–125 °C -50–125 °C -50–125 °C -50–125 °C -50–125 °C -50–125 °C -50–125 °C -50–125 °C -50–125 °C
Acceleration sensitivity 10 mV/g 10 mV/g 10 mV/g 10 mV/g 10 mV/g 10 mV/g 10 mV/g 10 mV/g 10 mV/g 10 mV/g
Status Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — ASA-068/050/0 (opens in a new tab) PDF — ASA-068/100/0 (opens in a new tab) PDF — ASA-068/150/0 (opens in a new tab) PDF — ASA-068/200/0 (opens in a new tab) PDF — ASA-068/250/0 (opens in a new tab) PDF — ASA-068/300/0 (opens in a new tab) PDF — ASA-068/350/0 (opens in a new tab) PDF — ASA-068/400/0 (opens in a new tab) PDF — ASA-068/450/0 (opens in a new tab) PDF — ASA-068/500/0 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It is a piezoelectric vibration accelerometer with an integrated amplifier for rotating machinery such as turbines, pumps and compressors. Nominal sensitivity is 10 mV/g at ±5%.

It requires 2–10 mA constant current, nominally 4 mA. In a hazardous area it must connect to an approved intrinsically safe circuit under the certificate voltage, current and power limits.

The integrated cable is documented up to 50 m, with optional stainless-steel protective tubing up to 10 m. Combined sensor-and-cable capacitance changes with length, so check the combination against the approved interface.

No. At 4 mA supply current, ±500 g is specified when available voltage exceeds 24 V; ±400 g is specified at 20 V and ±200 g at 18 V.

No. IP describes ingress protection, while Ex approval adds separate temperature, category and supply-chain conditions. Check both for the installation.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words