Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of FAMILY 4534-B
Frequency response 0.2–16000000 Hz
Operating temperature -60–150 °C
Phase response 1–10000 Hz
Acceleration sensitivity 9.8–490 mV/g

Models in the series

One column per model: what differs between the models of the series.

Models of FAMILY 4534-B compared by parameter
Parameter -4534-B– -4534-B-- -4534-B-001- -4534-B-002- -4534-B-004-
Mounted resonance frequency 38 kHz Not specified Not specified Not specified
Frequency response 0.2–12800 Hz 0.2–16000000 Hz 0.2–16000000 Hz 0.2–16000000 Hz
Technical specification details ±714 g indexed capacity; Uniaxial; General purpose; Clip mounting ±71 g indexed capacity; Uniaxial; General purpose; Clip mounting ±14 g indexed capacity; Uniaxial; General purpose; Clip mounting ±143 g indexed capacity; Uniaxial; General purpose; Clip mounting
Linearity reference Official indexed sensitivity tolerance: 10%. Official indexed sensitivity tolerance: 10%. Official indexed sensitivity tolerance: 10%. Official indexed sensitivity tolerance: 10%.
Outputs and interfaces Unknown Unknown Unknown Unknown
Operating temperature -60–150 °C -55–125 °C -55–125 °C -60–150 °C
Sampling rate limited by system readout True True True True
Repeatability reference HBK does not publish a separate scalar repeatability for every ordering code; use individual calibration and controlled mounting. HBK does not publish a separate scalar repeatability for every ordering code; use individual calibration and controlled mounting. HBK does not publish a separate scalar repeatability for every ordering code; use individual calibration and controlled mounting. HBK does not publish a separate scalar repeatability for every ordering code; use individual calibration and controlled mounting.
Phase response 1–10000 Hz 1–5000 Hz 2–1500 Hz 1–5 kHz
Acceleration sensitivity 9.8 mV/g 98 mV/g 490 mV/g 49 mV/g
Vibration sensor output Piezoelectric CCLD (IEPE); Analogue Piezoelectric CCLD (IEPE); Analogue Piezoelectric CCLD (IEPE); Analogue Piezoelectric CCLD (IEPE); Analogue
Number of axes 1 1 1 1
Number of measurement channels 1 1 1 1
Maximum non-destructive shock (peak) 10 000 g pk 10 000 g pk 10 000 g pk 10 000 g pk
Sampling rate reference Sensor bandwidth is indexed by HBK; the selected conditioner and DAQ determine digital sample rate. Sensor bandwidth is indexed by HBK; the selected conditioner and DAQ determine digital sample rate. Sensor bandwidth is indexed by HBK; the selected conditioner and DAQ determine digital sample rate. Sensor bandwidth is indexed by HBK; the selected conditioner and DAQ determine digital sample rate.
Static (DC) acceleration measurement False False False False
Status Active Active Active Active