IN-08x integrated-driver ECDS
IN-08x integrated-driver ECDS: sensors and measurement devices by Brüel & Kjær Vibro for vibration.
Download the datasheet (opens in a new tab) Visit the Brüel & Kjær Vibro site (opens in a new tab)
Models in the series
One column per model: what differs between the models of the series.
| Parameter | IN-081 | IN-083 | IN-084 | IN-085 | IN-08x series-wide technical data |
|---|---|---|---|---|---|
| Frequency response | 0–2.6 kHz | 0–2.6 kHz | 0–2.6 kHz | 0–2.6 kHz | Not specified |
| Operating temperature | 0–110 °C | 0–110 °C | 0–110 °C | 0–110 °C | Not specified |
| Protection class (DIN EN 60529) | IP54 | IP54 | IP54 | IP54 | Not specified |
| Status | Active | Active | Active | Active | Active |
| Datasheet | PDF — IN-081 (opens in a new tab) | PDF — IN-083 (opens in a new tab) | PDF — IN-084 (opens in a new tab) | PDF — IN-085 (opens in a new tab) | PDF — IN-08x series-wide technical data (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
These eddy-current sensors have an integrated oscillator and measure relative shaft displacement and vibration against a conductive metallic surface.
1.5 mm is the linear measuring range. The 2.4 mm range is documented with an additional 5% deviation, so it is not the same range at the same accuracy conditions.
No. The nominal −8 mV/µm value applies to 42CrMo4. Other materials have different sensitivities and require the measurement electronics to be calibrated for the target material.
It requires −18 to −30 VDC and a suitable voltage-signal input. The documented frequency band is DC to 2.6 kHz at −3 dB. Distinguish sensor power from signal voltage.
Additional conducting metal in the measurement field can distort results. Maintain the illustrated clearances from the shaft, shoulders and adjacent sensors. The specification lists IP54.
Get a quote or advice