TYPE 4326

TYPE 4326: sensors and measurement devices by HBK for vibration.

Visit the HBK site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of TYPE 4326
Frequency response 0.64–16000000 Hz
Operating temperature -60–288 °C

Models in the series

One column per model: what differs between the models of the series.

Models of TYPE 4326 compared by parameter
Parameter -4326–001- -4326--001- -4326-A– -4326-A-- -4326-A-001-
Technical specification details ±3000 g indexed capacity; Triaxial; Miniature/ESS; Clip mounting ±3000 g indexed capacity; Triaxial; General purpose; Clip mounting ±3000 g indexed capacity; Triaxial; General purpose; Clip mounting
Frequency response 0.64–16000000 Hz 0.64–10000 Hz 0.64–10000 Hz
Operating temperature -60–288 °C -60–175 °C -60–288 °C
Vibration sensor output Piezoelectric charge; Analogue Piezoelectric charge; Analogue Piezoelectric charge; Analogue
Sampling rate reference Sensor bandwidth is indexed by HBK; the selected conditioner and DAQ determine digital sample rate. Sensor bandwidth is indexed by HBK; the selected conditioner and DAQ determine digital sample rate. Sensor bandwidth is indexed by HBK; the selected conditioner and DAQ determine digital sample rate.
Static (DC) acceleration measurement False False False
Repeatability reference HBK does not publish a separate scalar repeatability for every ordering code; use individual calibration and controlled mounting. HBK does not publish a separate scalar repeatability for every ordering code; use individual calibration and controlled mounting. HBK does not publish a separate scalar repeatability for every ordering code; use individual calibration and controlled mounting.
Outputs and interfaces Unknown Unknown Unknown
Acceleration sensitivity 3.1 mV/g 3.1 mV/g 3.1 mV/g
Sampling rate limited by system readout True True True
Linearity reference Official indexed sensitivity tolerance: 20%. Official indexed sensitivity tolerance: 20%. Official indexed sensitivity tolerance: 20%.
Number of axes 3 3 3
Number of measurement channels 3 3 3
Status Active Active Active