VCM-3 Ex
From the VCM-3 condition monitoring series
VCM-3 condition monitoring: data acquisition systems by Brüel & Kjær Vibro for data acquisition.
- Frequency response
- 0.1–80000 Hz
- Number of measurement channels
- 24
Technical specification
Every engineering figure, laid out to scan quickly
| Number of measurement channels | 24 |
|---|---|
| ADC sampling rate | 204800 samples/s |
| Frequency response | 0.1–80000 Hz |
| Operating temperature | -30–60 °C |
| Protection class (DIN EN 60529) | IP20 |
| Technical specification details | 280 × 153.5 × 35 mm; 1.5 kg; 18–26 V DC; DIN-rail or wall mounting. |
| Repeatability reference | Repeatability of the complete sensor + VCM-3 chain is not published; validate the selected sensors, mounting and calibration route. |
| Sampling rate reference | Official VCM-3 specification: 204.8 kHz synchronous on all 12 dynamic channels; speed channels sample at 8 kHz and 4–20 mA process channels at 4 kHz. |
| Linearity reference | Official VCM-3 specification publishes AC/DC amplitude accuracy and process-input non-linearity for the monitor channels; it does not replace the attached sensor's calibration data. |
Values by configuration
These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.
| Interfaces | Ethernet |
|---|---|
| Interfaces | USB |
| Outputs and interfaces | Digital I/O |
| Outputs and interfaces | RS422 / RS485 |
| Outputs and interfaces | 4-20mA |
The industries we serve
Get a quote or advice