B&K measurement microphone sets + LAN-XI Microphones
B&K measurement microphone sets + LAN-XI: sensors and measurement devices by HBK for microphones.
Visit the HBK site (opens in a new tab)
Shared technical specifications for the series
Properties every model in the series has. What differs is in the models table below.
Range across models
The span covered by the models of the series together — not the range of each model.
| Microphone diameter | 0.125–0.5 inch |
|---|---|
| Frequency response | 0.07–140000 Hz |
| Maximum SPL | 110–184 dB SPL |
| ADC sampling rate | 131072–524288 samples/s |
| Microphone sensitivity | 0.08–1100 mV/Pa |
| Operating temperature | -170–125 °C |
| Number of measurement channels | 1–6 |
Models in the series
One column per model: what differs between the models of the series.
| Parameter | 4138-A-015 | 4138-B-006 | 4138-C-006 | 4138-L-006 | 4188-A-021 | 4188-A-031 | 4188-B-001 | 4188-C-001 | 4188-L-001 | 4189-A-021 | 4189-B-001 | 4189-C-001 | 4189-H-041 | 4189-L-001 | 4189-W-003 | 4190-B-001 | 4190-C-001 | 4190-L-001 | 4191-B-001 | 4191-C-001 | 4191-L-001 | 4192-B-001 | 4192-C-001 | 4192-L-001 | 4193-B-004 | 4193-C-004 | 4193-L-004 | 4938-A-011 | 4938-B-002 | 4938-C-002 | 4938-L-002 | 4939-B-002 | 4939-C-002 | 4939-L-002 | 4941-A-011 | 4941-B-002 | 4941-C-002 | 4941-L-002 | 4942-A-021 | 4942-A-031 | 4942-B-001 | 4942-C-001 | 4942-H-041 | 4942-L-001 | 4943-B-001 | 4943-C-001 | 4943-L-001 | 4944-A | 4944-B | 4944-W-005 | 4944-W-007 | 4944-W-010 | 4954-A | 4954-A-011 | 4954-B | 4955 | 4966-A-041 | 4966-H-041 | 4966-L-001 | 4971-H-041 | 4988-A |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Microphone diameter | 0.125 inch | 0.125 inch | 0.125 inch | 0.125 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.25 inch | 0.25 inch | 0.25 inch | 0.25 inch | 0.25 inch | 0.25 inch | 0.25 inch | 0.25 inch | 0.25 inch | 0.25 inch | 0.25 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.25 inch | 0.25 inch | 0.25 inch | 0.25 inch | 0.25 inch | 0.25 inch | 0.25 inch | 0.25 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.5 inch | 0.25 inch |
| Frequency response | 6.5–140000 Hz | 6.5–140000 Hz | 6.5–140000 Hz | 6.5–140000 Hz | 20–12500 Hz | 8–12500 Hz | 8–12500 Hz | 8–12500 Hz | 8–12500 Hz | 20–20000 Hz | 6.3–20000 Hz | 6.3–20000 Hz | 6.3–20000 Hz | 6.3–20000 Hz | 6.3–20000 Hz | 3.15–20000 Hz | 3.15–20000 Hz | 3.15–20000 Hz | 3.15–40000 Hz | 3.15–40000 Hz | 3.15–40000 Hz | 3.15–20000 Hz | 3.15–20000 Hz | 3.15–20000 Hz | 0.1–20000 Hz | 0.07–20000 Hz | 0.07–20000 Hz | 4–70000 Hz | 4–70000 Hz | 4–70000 Hz | 4–70000 Hz | 4–100000 Hz | 4–100000 Hz | 4–100000 Hz | 4–20000 Hz | 4–20000 Hz | 4–20000 Hz | 4–20000 Hz | 6.3–16000 Hz | 6.3–16000 Hz | 6.3–16000 Hz | 6.3–16000 Hz | 6.3–16000 Hz | 6.3–16000 Hz | 3.15–10000 Hz | 3.15–10000 Hz | 3.15–10000 Hz | 16–70000 Hz | 16–70000 Hz | 16–70000 Hz | 16–70000 Hz | 16–70000 Hz | 3–80000 Hz | 3–80000 Hz | 3–80000 Hz | 10–16000 Hz | 12.5–20000 Hz | 6.3–20000 Hz | 6.3–20000 Hz | 10–20000 Hz | 20–20000 Hz |
| Maximum SPL | 168 dB SPL | 168 dB SPL | 168 dB SPL | 168 dB SPL | 146 dB SPL | 146 dB SPL | 146 dB SPL | 146 dB SPL | 146 dB SPL | 146 dB SPL | 146 dB SPL | 146 dB SPL | 146 dB SPL | 146 dB SPL | 146 dB SPL | 148 dB SPL | 148 dB SPL | 148 dB SPL | 162 dB SPL | 162 dB SPL | 162 dB SPL | 162 dB SPL | 162 dB SPL | 162 dB SPL | 148 dB SPL | 148 dB SPL | 148 dB SPL | 172 dB SPL | 172 dB SPL | 172 dB SPL | 172 dB SPL | 164 dB SPL | 164 dB SPL | 164 dB SPL | 184 dB SPL | 184 dB SPL | 184 dB SPL | 184 dB SPL | 146 dB SPL | 146 dB SPL | 146 dB SPL | 146 dB SPL | 146 dB SPL | 146 dB SPL | 148 dB SPL | 148 dB SPL | 148 dB SPL | 169 dB SPL | 169 dB SPL | 169 dB SPL | 169 dB SPL | 169 dB SPL | 164 dB SPL | 164 dB SPL | 164 dB SPL | 110 dB SPL | 144 dB SPL | 144 dB SPL | 144 dB SPL | 146 dB SPL | 146 dB SPL |
| ADC sampling rate | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 524288 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 262144 samples/s | 131072 samples/s | 262144 samples/s | 131072 samples/s | 131072 samples/s | 524288 samples/s | 131072 samples/s | 524288 samples/s | 262144 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 262144 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 262144 samples/s | 131072 samples/s | 131072 samples/s | 262144 samples/s | 131072 samples/s | 262144 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 262144 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 262144 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 131072 samples/s | 524288 samples/s |
| Microphone sensitivity | 0.56 mV/Pa | 0.8 mV/Pa | 0.8 mV/Pa | 0.8 mV/Pa | 31.6 mV/Pa | 31.6 mV/Pa | 31.6 mV/Pa | 31.6 mV/Pa | 31.6 mV/Pa | 50 mV/Pa | 50 mV/Pa | 50 mV/Pa | 50 mV/Pa | 50 mV/Pa | 50 mV/Pa | 50 mV/Pa | 50 mV/Pa | 50 mV/Pa | 12.5 mV/Pa | 12.5 mV/Pa | 12.5 mV/Pa | 12.5 mV/Pa | 12.5 mV/Pa | 12.5 mV/Pa | 2 mV/Pa | 2 mV/Pa | 2 mV/Pa | 1.4 mV/Pa | 1.4 mV/Pa | 1.4 mV/Pa | 1.4 mV/Pa | 3.5 mV/Pa | 3.5 mV/Pa | 3.5 mV/Pa | 0.08 mV/Pa | 0.08 mV/Pa | 0.09 mV/Pa | 0.08 mV/Pa | 50 mV/Pa | 50 mV/Pa | 50 mV/Pa | 50 mV/Pa | 50 mV/Pa | 50 mV/Pa | 50 mV/Pa | 50 mV/Pa | 50 mV/Pa | 0.9 mV/Pa | 0.9 mV/Pa | 0.9 mV/Pa | 0.9 mV/Pa | 0.9 mV/Pa | 2.8 mV/Pa | 2.8 mV/Pa | 2.8 mV/Pa | 1100 mV/Pa | 48.4 mV/Pa | 48.4 mV/Pa | 48.4 mV/Pa | 12 mV/Pa | 11 mV/Pa |
| Interfaces | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet | Ethernet |
| Acoustic standard | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration | IEC 61094 measurement microphone; system class depends on selected set and analyzer configuration |
| Operating temperature | -30–100 °C | -20–100 °C | -30–100 °C | -30–100 °C | -30–100 °C | -30–100 °C | -30–100 °C | -30–100 °C | -30–100 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–125 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–125 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–100 °C | -20–100 °C | -170–100 °C | -20–100 °C | -20–100 °C | -20–80 °C | -20–80 °C | -20–80 °C | -20–100 °C | -20–60 °C | -20–125 °C | -20–60 °C | -20–125 °C | -20–80 °C |
| Microphone polarization | Externally polarized, 200 V | Classical | Externally polarized, 200 V | Classical | CCLD | Prepolarized | Prepolarized | Prepolarized | Classical | CCLD | Classical | Prepolarized | Prepolarized | Classical | Prepolarized | CCLD | Externally polarized, 200 V | Externally polarized, 200 V | Externally polarized, 200 V | Classical | Classical | Classical | Classical | Classical | Classical | Classical | Classical | Externally polarized, 200 V | Externally polarized, 200 V | Externally polarized, 200 V | Classical | Classical | Classical | Externally polarized, 200 V | Classical | Externally polarized, 200 V | Externally polarized, 200 V | Classical | CCLD | Prepolarized | Prepolarized | Prepolarized | CCLD | Prepolarized | Externally polarized, 200 V | Classical | Externally polarized, 200 V | CCLD | Prepolarized | Prepolarized | Prepolarized | Prepolarized | CCLD | Prepolarized | Prepolarized | Classical | Prepolarized | CCLD | Prepolarized | Prepolarized | Prepolarized TEDS |
| Number of measurement channels | 4 | 4 | 4 | 2 | 3 | 1 | 4 | 6 | 4 | 4 | 2 | 4 | 4 | 2 | 3 | 4 | 6 | 2 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 6 | 4 | 6 | 1 | 4 | 2 | 4 | 4 | 3 | 6 | 4 | 6 | 6 | 4 | 3 | 4 | 3 | 6 | 1 | 1 | 3 | 3 | 4 | 4 | 6 | 6 | 1 | 6 | 6 | 4 | 4 | 6 |
| Sound field | Pressure / coupler / confined space | Pressure / coupler / confined space | Pressure / coupler / confined space | Pressure / coupler / confined space | Free field / outdoor | Free field / outdoor | Free field / outdoor | Free field / outdoor | Free field / outdoor | Free field / outdoor | Free field / outdoor | Free field / outdoor | Free field / outdoor | Free field / outdoor | Free field / outdoor | Free field / outdoor | Free field / outdoor | Free field / outdoor | Free field / outdoor | Free field / outdoor | Free field / outdoor | Pressure / coupler / confined space | Pressure / coupler / confined space | Pressure / coupler / confined space | Pressure / coupler / confined space | Pressure / coupler / confined space | Pressure / coupler / confined space | Pressure / coupler / confined space | Pressure / coupler / confined space | Pressure / coupler / confined space | Pressure / coupler / confined space | Free field / outdoor | Free field / outdoor | Free field / outdoor | Pressure / coupler / confined space | Pressure / coupler / confined space | Pressure / coupler / confined space | Pressure / coupler / confined space | Diffuse / reverberant field | Diffuse / reverberant field | Diffuse / reverberant field | Diffuse / reverberant field | Diffuse / reverberant field | Diffuse / reverberant field | Diffuse / reverberant field | Diffuse / reverberant field | Diffuse / reverberant field | Pressure / coupler / confined space | Pressure / coupler / confined space | Pressure / coupler / confined space | Pressure / coupler / confined space | Pressure / coupler / confined space | Free field / outdoor | Free field / outdoor | Free field / outdoor | Free field / outdoor | Free field / outdoor | Free field / outdoor | Free field / outdoor | Pressure / coupler / confined space | Pressure / coupler / confined space |
| Status | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active | Active |
| Datasheet | PDF — 4138-A-015 (opens in a new tab) | PDF — 4138-B-006 (opens in a new tab) | PDF — 4138-C-006 (opens in a new tab) | PDF — 4138-L-006 (opens in a new tab) | PDF — 4188-A-021 (opens in a new tab) | PDF — 4188-A-031 (opens in a new tab) | PDF — 4188-B-001 (opens in a new tab) | PDF — 4188-C-001 (opens in a new tab) | PDF — 4188-L-001 (opens in a new tab) | PDF — 4955 (opens in a new tab) |
The industries we serve
Frequently asked questions
Answers to the most common questions about our products and services
The manufacturer describes Type 4138 as a pressure-field microphone for high-level and very-high-frequency measurements, and for confined spaces. The document lists a 6.5 Hz to 140 kHz range.
Type 4138 is externally polarized and requires 200 V. The product data specifies a classical preamplifier such as Type 2670 together with adaptor UA-0160.
The product data says sensitivity can be calibrated at 250 Hz with Pistonphone Type 4228 or at 1 kHz with Sound Calibrator Type 4231. Adaptor DP-0774 is used in both cases.
The product data describes Type 4955-A as optimized for handheld analyzers Types 2250, 2260, and 2270. Retain the A suffix because it identifies a distinct version from Type 4955.
No. Type 4188 is prepolarized and requires no external polarization voltage; it can be used with CCLD or classical preamplifiers. Match the preamplifier to the measurement system.
Get a quote or advice
Tell us what you need and an engineer will come back to you.