Range across the models of capaNCDT CSE/M
Number of measurement channels 1–4
Measuring range 0.5–3 mm
Recommended target diameter 6–20 mm
Resolution 0.00015–0.0009 µm
Measuring window 0–6 mm
Linearity 0.25–3 µm
Active area size (as specified) 3.9–9.8 mm
Weight 0.0035–0.08 kg
Minimum target diameter 6–10 mm
ADC sampling rate 5000–8500 samples/s
Accuracy 0.25–3 µm

Models in the series

One column per model: what differs between the models of the series.

Models of capaNCDT CSE/M compared by parameter
Parameter CSE05/M8 CSE1.25/M12 CSE2/M16 CSE3/M24
Protection class (DIN EN 60529) IP40 IP40 IP40 IP40
Number of measurement channels 4 1 4 4
Measuring range 0.5 mm 1.25 mm 2 mm 3 mm
Outputs and interfaces RS422 / RS485 RS422 / RS485 Analog 0-10V Analog 0-10V
Recommended target diameter 6 mm 10 mm 14 mm 20 mm
Resolution 0.00015 µm 0.000375 µm 0.0006 µm 0.0009 µm
Interfaces Ethernet Ethernet EtherCAT Ethernet
Measuring window 0–0.5 mm 0–0.625 mm 0–4 mm 0–6 mm
Linearity reference Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6530 (8-channel base) + DL6510 + CPM6011 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6230 + DL6220 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6222 + DL6222 controller contribution. Official sensor linearity from the current capaNCDT catalog; total measuring-channel linearity also includes the DT6110/IP controller contribution.
Linearity 0.25 µm 1.25 µm 2 µm 3 µm
Active area size (as specified) 3.9 mm 6.3 mm 8 mm 9.8 mm
Sampling rate reference DT6110/IP: IP68 single-channel controller with 1 kHz bandwidth DT6110: 1 kHz analog measurement bandwidth DT6120: 1 kHz analog bandwidth; up to 2 kSamples/s over RS485 DL6230: 5 kHz bandwidth; DT6230 digital rate 3.906 kSamples/s
Weight 0.0035 kg 0.0115 kg 0.035 kg 0.08 kg
Start of measuring range 0 mm 0 mm 0 mm 0 mm
Operating temperature -50–200 °C -50–200 °C -50–200 °C -50–200 °C
Minimum target diameter 6 mm 10 mm Not specified Not specified
Recommended mounting position 3.6 mm from sensor face 4.4 mm from sensor face 4.4 mm from sensor face 5.4 mm from sensor face
Temperature stability (µm/K) -0.02 µm/K -0.12 µm/K -0.16 µm/K -0.18 µm/K
Storage temperature -50–200 °C -50–200 °C -50–200 °C -50–200 °C
Technical specification details 0-0.5 mm model-level measuring interval 0-1.25 mm model-level measuring interval 0-2 mm model-level measuring interval 0-3 mm model-level measuring interval
Contact Non-contact Non-contact Non-contact Non-contact
ADC sampling rate 8500 samples/s 5000 samples/s 5000 samples/s 5000 samples/s
Accuracy 0.25 µm 1.25 µm 2 µm 3 µm
Status Active Active Active Active
Datasheet PDF — CSE05/M8 (opens in a new tab) PDF — CSE1.25/M12 (opens in a new tab) PDF — CSE2/M16 (opens in a new tab) PDF — CSE3/M24 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

CSE/M has an integrated mounting thread. Listed models are CSE05/M8, CSE1.25/M12, CSE2/M16 and CSE3/M24, so thread size depends on model.

The manufacturer specifies nuts on both sides and the tightening torque in the instructions. Mounting configuration is part of the specification conditions.

No. Thread size describes mounting. Recommended flat-target size is separately specified by model and measuring span.

A suitable triaxial cable for the model’s B/C socket and a capaNCDT controller are required. Assess performance for the complete head/cable/controller combination.

The table specifies IP40, not IP65 or IP68. Its mounting thread does not establish an ingress-protection rating.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words