Skip to content

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for ILD1320-25
Measuring range 25 mm
Start of measuring range 25 mm
End of measuring range 50 mm
Resolution 1 µm
Linearity 25 µm
Repeatability 2.5 µm
Light spot size on target at mid measuring range 55 × 60 µm
Operating temperature 0–50 °C
Protection class (DIN EN 60529) IP67
Contact Non-contact

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

Interfaces PROFINET
Interfaces RS422
Interfaces EtherCAT
Interfaces EtherNet/IP
Interfaces Ethernet
Interfaces USB
Measuring rate 4 kHz
Measuring rate 1 kHz
Outputs and interfaces Analog 0-10V
Outputs and interfaces RS422 / RS485
Selectable measuring rates 250 Hz
Selectable measuring rates 4 kHz
Selectable measuring rates 2 kHz
Selectable measuring rates 500 Hz
Selectable measuring rates 1 kHz
Request a quote for this product

Compatible accessories

Controllers

Complementary products

The industries we serve

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words