Skip to content

ILD1750-2DR

From the optoNCDT 1750 series

optoNCDT 1750: sensors and measurement devices by Micro-Epsilon for laser triangulation.

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for ILD1750-2DR
Measuring range 2 mm
Start of measuring range 24 mm
End of measuring range 26 mm
Linearity 1.6 µm
Repeatability 0.1 µm
Measuring rate 7.5 kHz
Operating temperature 0–50 °C
Protection class (DIN EN 60529) IP65
Contact Non-contact

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

Interfaces Ethernet
Interfaces PROFINET
Interfaces USB
Interfaces EtherCAT
Light spot diameter 0.08 mm
Light spot diameter 0.035 mm
Outputs and interfaces RS422 / RS485
Outputs and interfaces Analog 0-10V