Skip to content

optoNCDT 1900 Laser triangulation

optoNCDT 1900: sensors and measurement devices by Micro-Epsilon for laser triangulation.

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of optoNCDT 1900
Working distance 15–600 mm
Measuring range 2–500 mm
Start of measuring range 15–100 mm
End of measuring range 17–600 mm
Linearity 1–400 µm
Repeatability 0.1–40 µm
Light spot width X 0.055–0.95 mm
Light spot width Y 0.06–1.2 mm
Accuracy 1–400 µm

Models in the series

One column per model: what differs between the models of the series.

Models of optoNCDT 1900 compared by parameter
Parameter ILD1900-10 ILD1900-10 — Integrated cable 3 m, open ends ILD1900-10 — Pigtail 0.3 m, M12 17-pin ILD1900-100 ILD1900-100 — Integrated cable 3 m, open ends ILD1900-100 — Pigtail 0.3 m, M12 17-pin ILD1900-2 ILD1900-2 — Integrated cable 3 m, open ends ILD1900-2 — Pigtail 0.3 m, M12 17-pin ILD1900-200 ILD1900-200 — Integrated cable 3 m, open ends ILD1900-200 — Pigtail 0.3 m, M12 17-pin ILD1900-25 ILD1900-25 — Integrated cable 3 m, open ends ILD1900-25 — Pigtail 0.3 m, M12 17-pin ILD1900-50 ILD1900-50 — Integrated cable 3 m, open ends ILD1900-50 — Pigtail 0.3 m, M12 17-pin ILD1900-500 ILD1900-500 — Integrated cable 3 m, open ends ILD1900-500 — Pigtail 0.3 m, M12 17-pin ILD1900-6 ILD1900-6 — Integrated cable 3 m, open ends ILD1900-6 — Pigtail 0.3 m, M12 17-pin
Working distance 20–30 mm Not specified Not specified 50–150 mm Not specified Not specified 15–17 mm Not specified Not specified 60–260 mm Not specified Not specified 25–50 mm Not specified Not specified 40–90 mm Not specified Not specified 100–600 mm Not specified Not specified 17–23 mm Not specified Not specified
Outputs and interfaces Analog 0-10V Not specified Not specified Digital I/O Not specified Not specified Digital I/O Not specified Not specified Digital I/O Not specified Not specified Digital I/O Not specified Not specified Digital I/O Not specified Not specified Digital I/O Not specified Not specified RS422 / RS485 Not specified Not specified
Technical specification details 10 mm net measuring range; 20-30 mm sensor-to-target working window. Not specified Not specified Not specified Not specified Not specified 2 mm net measuring range; 15-17 mm sensor-to-target working window. Not specified Not specified Not specified Not specified Not specified 25 mm net measuring range; 25-50 mm sensor-to-target working window. Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 6 mm net measuring range; 17-23 mm sensor-to-target working window. Not specified Not specified
Measuring range 10 mm 10 mm 10 mm 100 mm 100 mm 100 mm 2 mm 2 mm 2 mm 200 mm 200 mm 200 mm 25 mm 25 mm 25 mm 50 mm 50 mm 50 mm 500 mm 500 mm 500 mm 6 mm 6 mm 6 mm
Start of measuring range 20 mm 20 mm 20 mm 50 mm 50 mm 50 mm 15 mm 15 mm 15 mm 60 mm 60 mm 60 mm 25 mm 25 mm 25 mm 40 mm 40 mm 40 mm 100 mm 100 mm 100 mm 17 mm 17 mm 17 mm
End of measuring range 30 mm 30 mm 30 mm 150 mm 150 mm 150 mm 17 mm 17 mm 17 mm 260 mm 260 mm 260 mm 50 mm 50 mm 50 mm 90 mm 90 mm 90 mm 600 mm 600 mm 600 mm 23 mm 23 mm 23 mm
Linearity 2 µm 2 µm 2 µm 30 µm 30 µm 30 µm 1 µm 1 µm 1 µm 100 µm 100 µm 100 µm 5 µm 5 µm 5 µm 10 µm 10 µm 10 µm 400 µm 400 µm 400 µm 1.8 µm 1.8 µm 1.8 µm
Repeatability 0.4 µm 0.4 µm 0.4 µm 4 µm 4 µm 4 µm 0.1 µm 0.1 µm 0.1 µm 8 µm 8 µm 8 µm 0.8 µm 0.8 µm 0.8 µm 1.6 µm 1.6 µm 1.6 µm Not specified < 20…40 µm < 20…40 µm 0.25 µm 0.25 µm 0.25 µm
Light spot width X 0.115 mm Not specified Not specified 0.38 mm Not specified Not specified 0.055 mm Not specified Not specified 0.95 mm Not specified Not specified 0.07 mm Not specified Not specified 0.095 mm Not specified Not specified 0.95 mm Not specified Not specified 0.057 mm Not specified Not specified
Light spot width Y 0.065 mm Not specified Not specified 0.46 mm Not specified Not specified 0.075 mm Not specified Not specified 1.2 mm Not specified Not specified 0.26 mm Not specified Not specified 0.3 mm Not specified Not specified 1.2 mm Not specified Not specified 0.06 mm Not specified Not specified
Interfaces Ethernet RS422 RS422 Ethernet RS422 RS422 Ethernet RS422 RS422 Ethernet RS422 RS422 Ethernet RS422 RS422 Ethernet RS422 RS422 Ethernet RS422 RS422 Ethernet RS422 RS422
Operating temperature 0–50 °C Not specified Not specified 0–50 °C Not specified Not specified 0–50 °C Not specified Not specified 0–50 °C Not specified Not specified 0–50 °C Not specified Not specified 0–50 °C Not specified Not specified 0–50 °C Not specified Not specified 0–50 °C Not specified Not specified
Protection class (DIN EN 60529) IP67 Not specified Not specified IP67 Not specified Not specified IP67 Not specified Not specified IP67 Not specified Not specified IP67 Not specified Not specified IP67 Not specified Not specified IP67 Not specified Not specified IP67 Not specified Not specified
Contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact Non-contact
Accuracy 2 µm Not specified Not specified 30 µm Not specified Not specified 1 µm Not specified Not specified 100 µm Not specified Not specified 5 µm Not specified Not specified 10 µm Not specified Not specified 400 µm Not specified Not specified 1.8 µm Not specified Not specified
ADC sampling rate 10000 samples/s Not specified Not specified 10000 samples/s Not specified Not specified 10000 samples/s Not specified Not specified 10000 samples/s Not specified Not specified 10000 samples/s Not specified Not specified 10000 samples/s Not specified Not specified 10000 samples/s Not specified Not specified 10000 samples/s Not specified Not specified
Measuring rate Not specified 10 kHz 10 kHz Not specified 10 kHz 10 kHz Not specified 10 kHz 10 kHz Not specified 10 kHz 10 kHz Not specified 10 kHz 10 kHz Not specified 10 kHz 10 kHz Not specified 10 kHz 10 kHz Not specified 10 kHz 10 kHz
Light spot size on target at mid measuring range Not specified 60 × 65 µm (MMR) 60 × 65 µm (MMR) Not specified 140 × 170 µm (MMR) 140 × 170 µm (MMR) Not specified 55 × 65 µm (MMR) 55 × 65 µm (MMR) Not specified 950 × 1200 µm (MMR) 950 × 1200 µm (MMR) Not specified 70 × 75 µm (MMR) 70 × 75 µm (MMR) Not specified 95 × 110 µm (MMR) 95 × 110 µm (MMR) Not specified 950 × 1200 µm (MMR) 950 × 1200 µm (MMR) Not specified 57 × 60 µm (MMR) 57 × 60 µm (MMR)
Status Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — ILD1900-10 (opens in a new tab) PDF — ILD1900-10 — Integrated cable 3 m, open ends (opens in a new tab) PDF — ILD1900-10 — Pigtail 0.3 m, M12 17-pin (opens in a new tab) PDF — ILD1900-100 (opens in a new tab) PDF — ILD1900-100 — Integrated cable 3 m, open ends (opens in a new tab) PDF — ILD1900-100 — Pigtail 0.3 m, M12 17-pin (opens in a new tab) PDF — ILD1900-2 (opens in a new tab) PDF — ILD1900-2 — Integrated cable 3 m, open ends (opens in a new tab) PDF — ILD1900-2 — Pigtail 0.3 m, M12 17-pin (opens in a new tab) PDF — ILD1900-200 (opens in a new tab) PDF — ILD1900-200 — Integrated cable 3 m, open ends (opens in a new tab) PDF — ILD1900-200 — Pigtail 0.3 m, M12 17-pin (opens in a new tab) PDF — ILD1900-25 (opens in a new tab) PDF — ILD1900-25 — Integrated cable 3 m, open ends (opens in a new tab) PDF — ILD1900-25 — Pigtail 0.3 m, M12 17-pin (opens in a new tab) PDF — ILD1900-50 (opens in a new tab) PDF — ILD1900-50 — Integrated cable 3 m, open ends (opens in a new tab) PDF — ILD1900-50 — Pigtail 0.3 m, M12 17-pin (opens in a new tab) PDF — ILD1900-500 (opens in a new tab) PDF — ILD1900-500 — Integrated cable 3 m, open ends (opens in a new tab) PDF — ILD1900-500 — Pigtail 0.3 m, M12 17-pin (opens in a new tab) PDF — ILD1900-6 (opens in a new tab) PDF — ILD1900-6 — Integrated cable 3 m, open ends (opens in a new tab) PDF — ILD1900-6 — Pigtail 0.3 m, M12 17-pin (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

No. The manual distinguishes the 10 kHz maximum from the 4 kHz factory setting. Select the operating rate for the surface and application.

A lower rate permits a longer exposure. The manufacturer recommends considering it for dark or shiny targets to improve the measurement result.

No. Integrated Industrial Ethernet versions coexist with variants needing an adapter. Select the exact model code and required EtherCAT, PROFINET or EtherNet/IP protocol.

No. It varies by model; the relevant table specifies typical values at 4 kHz and median 9. Preserve those test conditions.

The catalogue describes a 3 m open-ended integral cable or 0.3 m pigtail with a 17-pin M12 connector. Match extension cable and drawing to the configuration.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words