Measuring range 10 mm
Start of measuring range 20 mm
End of measuring range 30 mm
Working distance 20–30 mm
Linearity 2 µm
Repeatability 0.4 µm
Interfaces Ethernet
Operating temperature 0–50 °C
Protection class (DIN EN 60529) IP67
Technical specification details 10 mm net measuring range; 20-30 mm sensor-to-target working window.
Contact Non-contact

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

Light spot width X 0.115 mm
Light spot width X 0.06 mm
Light spot width X 0.12 mm
Light spot width Y 0.065 mm
Light spot width Y 0.15 mm
Light spot width Y 0.14 mm
Outputs and interfaces Analog 0-10V
Outputs and interfaces RS422 / RS485
Outputs and interfaces Digital I/O