Skip to content

thicknessGAUGE C.LP

thicknessGAUGE C.LP: sensors and measurement devices by Micro-Epsilon for measurement & 3d systems.

Download the datasheet (opens in a new tab) Visit the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of thicknessGAUGE C.LP
Protection class (DIN EN 60529) IP54

Models in the series

One column per model: what differs between the models of the series.

Models of thicknessGAUGE C.LP compared by parameter
Parameter C.LP-15/200 C.LP-15/400 C.LP-15/600
Protection class (DIN EN 60529) IP40 IP54 IP40
Interfaces Ethernet PROFINET Ethernet
System calibration type Automatic Automatic Automatic
System accuracy 1.2 µm 1.2 µm 1.2 µm
Outputs and interfaces OPC UA Analog 0-10V Analog 0-10V
Measuring range 15 mm Not specified Not specified
Resolution 0.2 µm 0.2 µm 0.2 µm
Storage temperature -20–65 °C -20–65 °C -20–65 °C
Technical specification details 15 mm thickness measuring range; 200 mm named measuring width. 15 mm thickness range, 400 mm measuring width, C-frame with two laser profile scanners. 15 mm thickness measuring range; 600 mm named measuring width.
Measuring rate 100 Hz 100 Hz 100 Hz
Repeatability reference Repeatability not stated in the reviewed official source. Not specified Repeatability not stated in the reviewed official source.
Humidity 5–95 %RH 5–95 %RH 5–95 %RH
Operating range 144 mm 144 mm 144 mm
Operating temperature 5–45 °C 5–45 °C 5–45 °C
Sampling rate reference Official maximum measurement or output rate: 100 Hz. Not specified Official maximum measurement or output rate: 100 Hz.
Maximum travel 380 mm 580 mm 780 mm
Laser class 2M 2M 2M
Interface options depending on system components PROFINET EtherNet/IP EtherNet/IP
Maximum material width 200 mm 400 mm 600 mm
ADC sampling rate 100 samples/s Not specified 100 samples/s
Working distance Not specified 0–144 mm Not specified
Status Active Active Active
Datasheet PDF — C.LP-15/200 (opens in a new tab) PDF — C.LP-15/400 (opens in a new tab) PDF — C.LP-15/600 (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

It uses opposed laser-profile sensors for thickness. Profiles support structured surfaces and strip-tilt handling according to the measurement program.

No. The catalogue specifies up to 100 Hz for C.LP. Do not use maximum head profile frequency as thickness-system rate.

Thickness span belongs to the thickness axis. Profile width and mechanical traverse width are separate dimensions, not one range filter.

No. It is a profile-based thickness system. General 3D geometry needs a corresponding configuration/program, such as the appropriate 3D family.

Heads need mutual alignment and calibrated baseline. Automatic calibration against the parked standard helps maintain stable thickness measurement.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words